A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring protein kinase and phosphatase reactions with matrix-assisted laser desorption/ionization mass spectrometry and capillary zone electrophoresis: comparison of the detection efficiency of peptide-phosphopeptide mixtures. | LitMetric

Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) and capillary zone electrophoresis (CZE) were evaluated for monitoring protein phosphatase and kinase reactions in vitro. Varying concentrations of peptide C (YIHLEKKYVRRDSG), peptide S (YLIEDNEYTARQGA) and kemptide (LARRSALG) mixed with their corresponding phosphorylated peptides, pC, pS and pkemptide, were analyzed. Comparison between the two techniques indicated that MALDI MS was less quantitative than CZE, showing a bias towards detection of the unphosphorylated peptide S and kemptide. In terms of sensitivity, the MALDI MS and CZE techniques are comparable. Protein kinase A phosphorylation of kemptide was monitored with both MALDI MS and CZE, whereas alkaline phosphatase dephosphorylation of pC could only be monitored with MALDI MS. The absence of inhibition with phosphatase or kinase buffers is a significant advantage of MALDI MS. In contrast to CZE, the MALDI spectra allow identification of the species analyzed by virtue of their mass. The results obtained emphasize the advantage of monitoring enzymatic reactions in buffer solutions using MALDI MS compared with CZE.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bms.1200230810DOI Listing

Publication Analysis

Top Keywords

monitoring protein
8
protein kinase
8
matrix-assisted laser
8
laser desorption/ionization
8
desorption/ionization mass
8
mass spectrometry
8
capillary zone
8
zone electrophoresis
8
maldi
8
phosphatase kinase
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!