A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of high-performance liquid chromatography and capillary electrophoresis in the analysis of somatostatin analogue peptides. | LitMetric

HPLC and CE methods were developed for analysis of somatostatin analogue (S-analogue) peptides utilizing triethylammonium phosphate-organic solvent modifier solvents as the CE buffer and HPLC eluent. Acetonitrile, methanol, ethanol and 2-propanol were applied as organic modifiers. The applicability of HPLC and CE systems was evaluated and compared. Optimum conditions for the separation were determined for both methods. Retention (migration) time, elution order and selectivity can be influenced by modifying the composition of the eluent (buffer) with organic solvents not only in HPLC but also in CE. Although the HPLC system reacted to changes in the organic solvent concentration in a much more sensitive way than the CE system did (from the point of view of retention time), CE proved to be a more suitable method for separating the peptides investigated. Baseline separation could be achieved within 6-9 min by CE, a result which was impossible to achieve with HPLC working in the isocratic mode. In CE the effect of the alcohols on migration times proved to be opposite to that of acetonitrile. Whereas ACN decreased, the alcohols increased the migration times in a concentration-dependent way. The results suggest that CE can be applied very advantageously in peptide analysis. Its performance regarding selectivity, resolution, theoretical plate number, duration and cost is comparable or sometimes superior to that of HPLC.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0021-9673(93)83308-fDOI Listing

Publication Analysis

Top Keywords

analysis somatostatin
8
somatostatin analogue
8
migration times
8
hplc
7
comparison high-performance
4
high-performance liquid
4
liquid chromatography
4
chromatography capillary
4
capillary electrophoresis
4
electrophoresis analysis
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!