Health risk in hospitals through airborne allergens for patients presensitised to latex.

Lancet

Professional Associations' Institute of Occupational Medicine Institute, Ruhr-University of Bochum, Germany.

Published: November 1993

Two nurses had to stop practicing because of severe work-related allergic respiratory or systemic symptoms. Both developed similar symptoms within a short time when they attended hospitals as outpatients or visitors or consulted a doctor or dentist, even when they had no direct contact with latex articles. The airborne latex allergen concentration in one room that induced symptoms was 128 ng per m3. In skinprick tests both women showed positive reactions to the phosphated cornstarch powder used to prevent latex gloves sticking together, but only when the powder had been in contact with latex. This powder seems a likely vehicle for the airborne latex allergen.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0140-6736(93)92127-fDOI Listing

Publication Analysis

Top Keywords

contact latex
8
airborne latex
8
latex allergen
8
latex
6
health risk
4
risk hospitals
4
hospitals airborne
4
airborne allergens
4
allergens patients
4
patients presensitised
4

Similar Publications

Background: Angioedema is a condition marked by sudden, intense swelling of the subcutaneous and submucosal tissues, typically associated with hypersensitivity reactions, genetic mutations, or reactions to medications. It can also result from contact with allergens such as nickel, leading to dermatitis.

Case Presentation: A 12-year-old girl presented at our Pediatric Immunology and Allergology service with recurrent labial angioedema for over a year, linked to the consumption of legumes and tomatoes, and following the use of a metal flute.

View Article and Find Full Text PDF

Background: Anaphylaxis is a systemic allergic reaction that is potentially life-threatening. Occupational anaphylaxis is an anaphylaxis that occurs in an occupational context. In this position paper, we propose diagnostic criteria for occupational anaphylaxis and provide an overview of the current state of knowledge in terms of prevalence, triggers, prevention, and management.

View Article and Find Full Text PDF

We study the influence of airborne CO on the charge state of carboxylate stabilized polymer latex particles suspended in aqueous electrolytes. We combine conductometric experiments interpreted in terms of Hessinger's conductivity model with Poisson-Boltzmann cell (PBC) model calculations with charge regulation boundary conditions. Without CO, a minority of the weakly acidic surface groups are dissociated and only a fraction of the total number of counter-ions actually contribute to conductivity.

View Article and Find Full Text PDF

Efficacy of Disinfectants for Monkeypox Virus Inactivation on High Touch Surface Materials in Low-Resource Settings.

Environ Sci Technol

November 2024

Department of Civil Engineering, University of British Columbia, 2002-6250 Applied Science Lane, Vancouver, British Columbia V6T 1Z4, Canada.

Disinfection efficacy tests were conducted on surface carriers inoculated with the monkeypox virus (MPXV) by applying six disinfectant solutions (and three controls) on six surfaces common in low-resource settings: four nonporous surfaces (stainless steel, glass, plastic, and latex) and two porous surfaces (ceramic and wood). Disinfectants were wiped on carriers in triplicate, with a 1 min contact time: 0.05 and 0.

View Article and Find Full Text PDF