A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulsewave velocity measurement using a new real-time MR-method. | LitMetric

Pulsewave velocity measurement using a new real-time MR-method.

Magn Reson Imaging

Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum (dkfz), Heidelberg, Germany.

Published: April 1995

A new, one-dimensional method for the measurement of pulsewave velocities using real-time magnetic resonance (MR) imaging is presented. The measurement sequence is essentially of a RACE-type (Real Time Acquisition and Evaluation) with interleaved acquisition in two not necessarily parallel slices. In each slice the blood flow velocity perpendicular to the slice orientation was monitored. From the relative time difference of blood flow activity and the slice distance, pulsewave velocities were calculated. With a time resolution of 13 ms an overall acquisition time of 3.3 s was achieved. A method for suppression of signal contributions from stationary tissue along the axis of projection is discussed on the basis of a simplified mathematical model. Preliminary volunteer studies show that pulsewave velocities in the range of 1-10 m/s can be measured with an uncertainty of about 0.6 m/s at a conventional 1.5 T imager with a gradient system of maximal 10 mT/m.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0730-725x(94)00077-gDOI Listing

Publication Analysis

Top Keywords

pulsewave velocities
12
blood flow
8
pulsewave
4
pulsewave velocity
4
velocity measurement
4
measurement real-time
4
real-time mr-method
4
mr-method one-dimensional
4
one-dimensional method
4
method measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!