A simple traction-countertraction technique using common and readily available materials was successfully used to remove infected pacemaker leads from two patients. The specific methodology is presented. Although somewhat technically demanding, this approach appears safe and cost-effective. This method provides another way to remove pacemaker leads without resorting to thoracotomy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1540-8159.1994.tb02385.x | DOI Listing |
Indian Pacing Electrophysiol J
December 2024
Intermountain Heart Institute - Utah Valley Hospital, Salt Lake City, Utah, USA.
Introduction: The advancement of medical technology has introduced leadless pacemakers (LPMs) as a significant innovation in cardiac pacing, offering potential advantages over traditional ventricular transvenous pacemakers. This report explores the application of LPMs in two patients with complex valvular histories, particularly those with mechanical tricuspid valves.
Case Reports: The first case involves a 60-year-old male with a history of rheumatic heart disease and triple valve replacement who developed a high-grade AV block.
Pacing Clin Electrophysiol
December 2024
Department of Cardiology, Medical University of Lublin, Lublin, Poland.
Transvenous extraction of the leads in children is associated with a higher risk of serious complications, that is why it is reluctantly performed. Unfortunately, this conservative approach has been associated with secondary complications (tricuspid valve dysfunction and bilateral venous obstruction), adverse events during lead removal procedure and recanalization and stenting of chest veins. We present a case of a 27-year-old female with a pacemaker and insertion of two new leads on the opposite side of the chest leaving the old ones in place.
View Article and Find Full Text PDFBMC Cardiovasc Disord
December 2024
Department of Cardiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China.
Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.
View Article and Find Full Text PDFNeuromodulation
December 2024
StimAire Corporation, Tucson, AZ, USA.
Introduction: Moderate-to-severe obstructive sleep apnea (OSA) affects a large segment of the US population and is characterized by repetitive and reversible obstruction of the upper airway during sleep. Untreated OSA is associated with increased incidence of heart attack, stroke, and motor vehicle accidents due to sleepiness. Continuous positive airway pressure is often prescribed, but most patients with OSA are nonadherent.
View Article and Find Full Text PDFPragmat Obs Res
December 2024
BIOTRONIK Inc., Lake Oswego, OR, 97035, USA.
Background: As part of Electrophysiology Predictable and Sustainable Implementation of National Registries (EP PASSION), a multi-stakeholder collaboration between the US Food and Drug Administration (FDA), academic and society partners, and cardiovascular implantable electronic device manufacturers, a 5-year bradycardia lead study transitioned from a traditional post-approval study (PAS) to a real-world data (RWD) approach using a novel method to evaluate chronic cardiac lead complications.
Methods: Lead complications were identified using a combination of diagnosis and procedure codes from 2013 to 2020 fee-for-service Medicare claims data along with BIOTRONIK device registration and Medical Device Reporting data from patients implanted between 2013 and 2015 with a Solia S lead. A proof-of-concept analysis was performed using McNemar's test to compare lead complications reported in the traditional PAS with lead complications identified in the RWD.