A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aneurysms of the descending thoracic aorta: three hundred sixty-six consecutive cases resected without paraplegia. | LitMetric

Aneurysms of the descending thoracic aorta: three hundred sixty-six consecutive cases resected without paraplegia.

J Vasc Surg

Department of Cardiovascular and Thoracic Surgery, Hôpital du Sacré-Coeur de Montréal, University of Montréal, QC, Canada.

Published: March 1995

Purpose: The aim of this study was to present a 20-year experience with a single method of passive distal perfusion during descending thoracic aortic aneurysm resection.

Methods: Aortic repair with a Dacron graft interposition was performed for 366 consecutive aneurysms located between the left subclavian artery and the crux of the diaphragm. The extent of aorta resected in 335 patients (91.5%) represented one third or less of the aortic length. A 9 mm Gott shunt was cannulated proximally into the ascending aorta (235 cases), the aortic arch (60 cases), the descending aorta (68 cases), or the left ventricle (3 cases) and inserted distally into the descending aorta (232 cases), the femoral artery (127 cases), or the abdominal aorta (7 cases). Shunt flows were recorded in 91 cases and varied from 1100 ml to 4900 ml/min, (mean 2526 ml/min). Distal pressure during shunting was measured in 62 patients. It varied from 15 to 120 mm Hg (mean 64.5 mm Hg). The aortic cross-clamp time varied from 8 to 124 minutes (mean 30 minutes).

Results: The hospital death rate was 12% overall and 9.9% (35/351) if ruptured aneurysms are excluded. Among 359 operating room survivors, neither immediate nor delayed ischemic spinal cord deficit occurred. Transient renal dysfunction occurred in nine patients (2.4%) and kidney failure in one (0.2%). Five deaths (1.3%) were shunt related.

Conclusion: Distal perfusion with the 9 mm Gott shunt has proven to be an effective method to preserve spinal cord function. The limited extent of aorta resected and the brief aortic cross-clamp time may also be interactive factors of protection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0741-5214(95)70280-6DOI Listing

Publication Analysis

Top Keywords

cases
9
descending thoracic
8
distal perfusion
8
extent aorta
8
aorta resected
8
gott shunt
8
descending aorta
8
aorta cases
8
aortic cross-clamp
8
cross-clamp time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!