Study of the surface characteristics of magnetron-sputter calcium phosphate coatings.

J Biomed Mater Res

University of Nijmegen, Department of Oral Function, Dental School, The Netherlands.

Published: December 1994

Plasma-sprayed hydroxylapatite coatings on metals such as titanium have been investigated for many years and have shown a good biocompatibility when implanted in bony tissues. Radiofrequency magnetron sputtering was used as an alternative method to deposit thin films of hydroxylapatite on titanium substrates. X-ray diffraction demonstrated that the sputtered layer was crystalline with a preferred (001) crystallographic orientation with the C-axis perpendicular to the substrate surface. Scanning electron microscopy showed that the deposited films had a uniform and dense structure. The calcium phosphate ratio varied between 1.5 and 2.0, as determined by energy-dispersive X-ray analysis. The in vitro dissolution appeared to be determined by the degree of the coating's crystallinity.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.820281213DOI Listing