We developed a semi-automated retroillumination image analysis system which combines speed, ease of operation and interactive analysis. The system measures cataract area and integral of cataract density (ID). For system reproducibility evaluation, 20 eyes with posterior subcapsular opacities were captured twice by two photographers. Variability was estimated under a random effects analysis of variance model. Measurement errors for area and for ID were each small contributors to total variability (the sum of variability between study eyes plus measurement error), being 0.4% and 0.1% respectively. The largest contributor to area measurement error was image analysis variability (97%). For ID measurement error, the variability in images (44%) and in image analysis (46%) were major contributors. The reproducibility is comparable to previously described retroillumination analysis systems. This easy to use system may therefore be useful in clinical research studies including possible clinical trials of anti-cataract drugs.

Download full-text PDF

Source
http://dx.doi.org/10.1038/eye.1994.162DOI Listing

Publication Analysis

Top Keywords

image analysis
16
analysis system
12
measurement error
12
posterior subcapsular
8
subcapsular opacities
8
retroillumination image
8
analysis
7
system
5
variability
5
reproducibility study
4

Similar Publications

Background: For radiotherapy of head and neck cancer (HNC) magnetic resonance imaging (MRI) plays a pivotal role due to its high soft tissue contrast. Moreover, it offers the potential to acquire functional information through diffusion weighted imaging (DWI) with the potential to personalize treatment. The aim of this study was to acquire repetitive DWI during the course of online adaptive radiotherapy on an 1.

View Article and Find Full Text PDF

Background: He's team have recently developed a new Coronary Artery Tree description and Lesion EvaluaTion (CatLet) angiographic scoring system, which is capable of accounting for the variability in coronary anatomy, and risk-stratifying patients with coronary artery disease. Preliminary studies have demonstrated its superiority over the the Synergy between percutaneous coronary intervention with Taxus and Cardiac Surgery (SYNTAX) score with respect to outcome predictions for acute myocardial infarction (AMI) patients. However, there are fewer studies on the prognostic in chronic coronary artery disease(CAD).

View Article and Find Full Text PDF

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

The generation of retinal models from human induced pluripotent stem cells holds significant potential for advancing our understanding of retinal development, neurodegeneration, and the in vitro modeling of neurodegenerative disorders. The retina, as an accessible part of the central nervous system, offers a unique window into these processes, making it invaluable for both study and early diagnosis. This study investigates the impact of the Frontotemporal Dementia-linked IVS 10 + 16 MAPT mutation on retinal development and function using 2D and 3D retinal models derived from human induced pluripotent stem cells.

View Article and Find Full Text PDF

Background: Fibrotic types of interstitial lung abnormalities seen on high-resolution computed tomography scans, characterised by traction bronchiolectasis/bronchiectasis with or without honeycombing, are predictors of progression and poor prognostic factors of interstitial lung abnormalities. There are no reports on the clinical characteristics of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans. Therefore, we aimed to examine these clinical characteristics and clarify the predictive factors of fibrotic interstitial lung abnormalities on high-resolution computed tomography scans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!