The effect of the route administration on the distribution of radioiodinated OV-TL 3 F(ab')2 was studied in Balb/c female mice with intraperitoneal or subcutaneous ovarian carcinoma xenografts. In the intraperitoneal tumour model in which both ascites and solid tumour deposits were present, intraperitoneal administration resulted in a lower estimated radiation dose to blood as compared with intravenous administration. In this model normalization to equal estimated radiation doses to blood for both routes of administration indicated that a twice as high estimated radiation dose can be guided to solid intraperitoneal tumour deposits following intraperitoneal administration. Evacuation of ascitic tumour cells prior to monoclonal antibody injection further increased the estimated radiation dose to solid intraperitoneal tumour deposits following intraperitoneal delivery. Following simultaneous intravenous and intraperitoneal injection of the monoclonal antibody, tissue uptake showed no relevant differences in the subcutaneous tumour model. Overall, the intraperitoneal route of administration was found to be the best choice for therapeutic delivery of iodine-131 labelled monoclonal antibodies.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00182351DOI Listing

Publication Analysis

Top Keywords

estimated radiation
16
route administration
12
intraperitoneal tumour
12
tumour deposits
12
deposits intraperitoneal
12
radiation dose
12
intraperitoneal
9
radioiodinated ov-tl
8
ov-tl fab'2
8
tumour model
8

Similar Publications

Ra, Th, and K levels in various foods frequently consumed by Egyptians were determined using a gamma-ray spectrometer based on the germanium detector (HPGe). Activity concentrations of Ra, Th, and K were in the range of < 0.10 to 0.

View Article and Find Full Text PDF

H*10 neutron dosimetry (unlike gamma dosimetry), requires consideration of neutron energy spectra due to the 20× variation of the weight factor over the thermal-to-fast energy range, as well as the neutron radiation field dose rates ranging from cosmic, ~.01 μSv h-1 levels to commonly encountered ~10-200 μSv h-1 in nuclear laboratories/processing plants, and upwards of 104 Sv h-1 in nuclear reactor environments. This paper discusses the outcome of the comparison of spectrum-weighted neutron dosimetry covering thermal-to-fast energy using the novel H*-TMFD spectroscopy-enabled sensor system in comparison with measurements using state-of-the-art neutron dosimetry systems at SRNS-Rotating Spectrometer (ROSPEC), and non-spectroscopic Eberline ASP2E ("Eberline") and Ludlum 42-49B ("Ludlum") survey instrumentation.

View Article and Find Full Text PDF

Radiation Dose to Occupational Dosimeters Brought on Commercial Air Travel.

Health Phys

January 2025

Department of Radiation Oncology & Medical Physics, Inova Health Systems, Fairfax, Virginia.

Occupational radiation dosimeters that return high readings cannot always be explained by circumstances in the workplace. For this experiment, a series of optically stimulated luminescence (OSL) dosimeters were brought to airports to estimate the radiation dose OSLs would receive should a worker accidentally bring their dosimeter with them during travel. The OSLs returned readings between 0.

View Article and Find Full Text PDF

Purpose: Bodyweight loss is commonly found in Nasopharyngeal Carcinoma patients during Concurrent Chemo-radiotherapy (CCRT) and has implications for treatment decisions. However, the prognostic value of this weight loss remains uncertain. We addressed it by proposing a novel index Weight Censorial Score (WCS) that characterizes the patient-specific CCRT response on actual to estimated weight loss.

View Article and Find Full Text PDF

MR imaging of proton beam-induced oxygen depletion.

Med Phys

January 2025

OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany.

Background: Previous studies have shown that in-beam magnetic resonance imaging (MRI) can be used to visualize a proton beam during the irradiation of liquid-filled phantoms. The beam energy- and current-dependent local image contrast observed in water was identified to be predominantly caused by beam-induced buoyant convection and associated flow effects. Besides this flow dependency, the MR signal change was found to be characterized by a change in the relaxation time of water, hinting at a radiochemical contribution, which was hypothesized to lie in oxygen depletion-evoked relaxation time lengthening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!