Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0002-9149(99)80563-3 | DOI Listing |
Comput Struct Biotechnol J
December 2024
Institute of Molecular and Genomic Medicine, National Health Research Institutes, Miaoli 350, Taiwan.
An AI-assisted algorithm has been developed to improve the detection of significant coronary artery disease (CAD) in high-risk individuals who have normal electrocardiograms (ECGs). This retrospective study analyzed ECGs from patients aged ≥ 18 years who were undergoing coronary angiography to obtain a clinical diagnosis at Chang Gung Memorial Hospital in Taiwan. Utilizing 12-lead ECG datasets, the algorithm integrated features like time intervals, amplitudes, and slope between peaks, a total of 561 features, with the XGBoost model yielding the best performance.
View Article and Find Full Text PDFNature
January 2025
German Centre for Cardiovascular Research (DZHK), Partner Site Lower Saxony, Göttingen, Germany.
Cardiomyocytes can be implanted to remuscularize the failing heart. Challenges include sufficient cardiomyocyte retention for a sustainable therapeutic impact without intolerable side effects, such as arrhythmia and tumour growth. We investigated the hypothesis that epicardial engineered heart muscle (EHM) allografts from induced pluripotent stem cell-derived cardiomyocytes and stromal cells structurally and functionally remuscularize the chronically failing heart without limiting side effects in rhesus macaques.
View Article and Find Full Text PDFR I Med J (2013)
February 2025
Alpert Medical School of Brown University, Department of Medicine, Division of Cardiology, Rhode Island Hospital.
Cardiac Positron Emission Tomography (PET) can be used for the assessment of myocardial perfusion. Compared to other cardiac imaging techniques, notably Single Photon Emission Computer Tomography (SPECT), cardiac PET offers superior image resolution, higher accuracy, quantitative measures of myocardial perfusion, lower radiation exposure, and shorter image acquisition time. However, PET tends to be costlier and less widely available than SPECT due to the specialized equipment needed for generating the necessary radiotracers.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Open Heart
January 2025
Cardiology, Hospital Alvaro Cunqueiro, Vigo, Spain.
Introduction: ST-elevation myocardial infarction (STEMI) is one of the most prevalent presentations in young patients. It is essential to emphasise that each minute of delay in providing medical care is negatively correlated to the patient's prognosis. The present study was carried out to evaluate the ischaemia-reperfusion times in patients ≤40 years of age versus individuals >40 years of age and their association with mortality and major adverse cardiac event (MACE) over the long term.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!