Experimental pulse oximetry devices, similar to the existing systems used in adult and neonatal monitoring, can be used on the fetus to provide safe, and rapid information about oxygenation. They have been calibrated using fetal lambs and validated in human cross-sectional studies. Experiments have shown that fetal oxygen saturation decreases during normal labour, and drops after a uterine contraction especially with oxytocin-induced tachysystole. When the mother is given oxygen the fetal oxygen saturation increases. Readings are effected by caput and movement, and trends seem to be more meaningful than absolute values. Pulse oximetry can predict fetal outcome and a normal oxygen saturation result is specific for a good outcome perhaps even if the CTG is abnormal. However the technique is still experimental and there is insufficient data to support its use as a replacement for fetal blood sampling or a discriminator for an abnormal fetal heart trace.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1479-828x.1994.tb01263.x | DOI Listing |
J Sports Sci
January 2025
Department of Tourism, Sport and Society, Lincoln University, Christchurch, New Zealand.
To determine muscle oxygenation with continuous blood flow restriction (BFR) training in high load (HL), 80% one-repetition maximum (1RM) and low load (LL), 30% 1RM squat exercises. In week-2 of a 4-week resistance training programme as part of their 3-set training routine, two groups of athletes ( = 4 each), one performing HL training with low cuff pressure (20% arterial occlusion pressure (AOP)), the other LL training with high cuff pressure (60% AOP) had muscle oxygenation assessed with near-infrared spectrophotometry (NIRS), arterial oxygen saturation (SPO), heart rate (HR), barbell velocity and ratings of perceived exertion (RPE) during barbell back squats (BBS). Changes in the vastus lateralis oximetry were compared to pre- and post-training squat (1RM).
View Article and Find Full Text PDFJ Phys Chem B
January 2025
Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, Morgantown, West Virginia 26506, United States.
measurement and mapping of oxygen levels within the tissues are crucial in understanding the physiopathological processes of numerous diseases, such as cancer, diabetes, or peripheral vascular diseases. Electron paramagnetic resonance (EPR) associated with biocompatible exogenous spin probes, such as Ox071 triarylmethyl (TAM) radical, is becoming the new gold standard for oxygen mapping in preclinical settings. However, these probes do not show tissue selectivity when injected systemically, and they are not cell permeable, reporting oxygen from the extracellular compartment only.
View Article and Find Full Text PDFFront Pediatr
January 2025
Department of Neonatology, KK Women's and Children's Hospital, Singapore, Singapore.
Mid-trimester preterm premature rupture of membranes is a rare complication of pregnancy associated with significant maternal and fetal risks. The ensuing prolonged oligohydramnios can lead to fetal pulmonary hypoplasia. In addition, there is an increased risk of miscarriage, preterm birth, and chorioamnionitis, contributing to septic morbidity in the mother-baby dyad.
View Article and Find Full Text PDFNat Sci Sleep
January 2025
Sleep Center, Department of Geriatric Respiratory, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, People's Republic of China.
Purpose: Approximately 30% of patients with sleep-disordered breathing (SDB) present with masked hypertension, primarily characterized by elevated nighttime blood pressure. This study aimed to develop a hypertension prediction model tailored for primary care physicians, utilizing simple, readily available predictors derived from type IV sleep monitoring devices.
Patients And Methods: Participants were recruited from communities in Guangdong Province, China, between April and May 2021.
PLoS One
January 2025
European IPF/ILD Registry and Biobank (eurIPFreg/bank, eurILDreg/bank), Giessen, Germany.
Background And Aims: Predicting progression and prognosis in Interstitial Lung Diseases (ILD), especially Idiopathic Pulmonary Fibrosis (IPF) and Progressive Pulmonary Fibrosis (PPF), remains a challenge. Integrating patient-centered measurements is essential for earlier and safer detection of disease progression. Home monitoring through e-health technologies, such as spirometry and oximetry connected to smartphone applications, holds promise for early detection of ILD progression or acute exacerbations, enabling timely therapeutic interventions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!