Although the flow-through catheter (FTC) system has been useful and satisfactorily accurate for gastrointestinal manometry, we hypothesized that a cylindrical, liquid-filled balloon would also accurately reflect stress imposed by a sphincter. Latex balloons were fitted over the side ports of a closed-end catheter. The responses of the balloon and FTC system were compared in a cylindrical chamber commonly identified as a Starling resistor. Independent, constant-pressure sources were used to control both the inwardly directed "contact pressure" of the Starling resistor (Ps) and the intraluminal fluid pressure (P(lum)). The balloon transducers responded linearly and accurately (slope = 1) to changes in both Ps and P(lum) within the test range (0-200 mmHg, 0-26.7 kPa). When either P(lum) or Ps was held constant and the other changed, the balloon transducers always accurately measured the higher of the two pressures. Although the performance of the FTC system was improved after the Starling resistor was lubricated, the FTC system sometimes responded inaccurately to changes in Ps. The ability of the balloon transducers to measure the contractions of the lower esophageal sphincter and of the esophagus was demonstrated. We conclude that the balloon transducer can measure sphincter pressure accurately and suggest that, in certain circumstances, it might be advantageous relative to the FTC system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1139/y94-136 | DOI Listing |
Analyst
January 2025
Faculty of Physics, M.V. Lomonosov Moscow State University, 1-2 Leninskie Gory, Moscow, 119991, Russia.
The issue of variability introduced into blood plasma and serum analysis by preanalytical procedures is the major obstacle to obtaining accurate and reproducible results. While the question of how to overcome this issue has been discussed in biochemical detection of analytes and omics technologies, its relevance to the field of optical spectroscopy remains mostly unexplored. In this work, we evaluated the freeze-thaw cycle (FTC)-induced alternations in blood serum optical properties by means of autofluorescence and Raman spectroscopy, including surface-enhanced Raman spectroscopy (SERS).
View Article and Find Full Text PDFSci Total Environ
January 2025
University of Bath, Department of Chemistry, Bath BA2 7AY, United Kingdom; Centre of Excellence in Water-Based Early Warning Systems for Health Protection, University of Bath, Bath BA25RX, United Kingdom.
The production of organic-mineral fertilizers from sewage sludge is one of the ecological options in their management. Though, pharmaceuticals and their derivatives, which accumulate in the sludge, could be a problem due to their impacts on the environment. This manuscript aimed at better understanding of risks posed by antimicrobial agents (AAs) in sludge-based fertilizers.
View Article and Find Full Text PDFHIV Res Clin Pract
December 2025
National Heart and Lung Institute, Imperial College London, London, UK.
Introduction: The BIC-T&T study aimed to determine the efficacy of bictegraviremtricitabine/tenofovir alafenamide (BIC/F/TAF) and darunavir/cobicistat/emtricitabinetenofovir alafenamide (DRV/c/F/TAF) at suppressing viral load in a two-arm, open-label, multi-centre, randomised trial under a UK test-and-treat setting. This sub-study aimed to evaluate potential off-target cardiovascular impact by examining platelet function.
Methods: Platelets were isolated by centrifugation of citrated blood from participants attending Chelsea and Westminster Hospital or St Mary's Hospital at Week 48 following enrolment.
Clin Chem Lab Med
January 2025
Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.
The main stakeholders in external quality assessment (EQA) programs are the participants, in whose interests these challenges are ultimately organised. EQA schemes in the medical field contribute to improving the quality of patient care by evaluating the analytical and diagnostic quality of laboratory and point-of-care tests (POCT) by independent third parties and, if necessary, pointing out erroneous measurement results and analytical or diagnostic improvement potential. Other benefits include the option of using EQA samples for other important laboratory procedures, such as the verification or validation of diagnostic medical devices (IVD-MDs), a contribution to the estimation of measurement uncertainty, a means of training and educating laboratory staff through educational EQA programmes or samples, or even for independent and documented monitoring of staff competence, such as on samples with unusual or even exceptional characteristics.
View Article and Find Full Text PDFInt Urol Nephrol
January 2025
Department of Urology, Faculty of Health Sciences, Steve Biko Academic Hospital, University of Pretoria, Pretoria, South Africa.
Purpose: Contemporary antiretroviral (ARV) medications are used by millions of men for HIV treatment worldwide. Limited data exist on their direct effect on sperm motility. This pilot study hypothesizes that in vitro exposure to ARVs will reduce sperm kinematic and motility parameter values.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!