This study evaluates the in vitro accuracy and clinical repeatability of volumes derived by a new algorithm for three-dimensional reconstruction of cavity surfaces based on echocardiographic apical images obtained by probe rotation. The accuracy of the method was tested in latex phantoms (true volumes, 32 to 349 cm3) with (n = 9) or without (n = 9) rotational symmetry around the midcavitary long axis. Repeatability of left ventricular volumes was assessed in subjects without (n = 5) or with (n = 10) myocardial disease. Estimated phantom volumes obtained from four (three) imaging planes were close to true volumes with a mean difference +/- SD of 0 +/- 2 (2 +/- 3) cm3 in symmetric and 1 +/- 3 (4 +/- 4) cm3 in asymmetric objects. Biplane and single-plane volume estimates were less accurate. Interobserver and intraobserver repeatability of three-dimensional left ventricular volumes was good for analysis (coefficients of variation: 3.5% to 6.2%) and was lower for recording (coefficients of variation: 7.4% to 10.9%). Hence the present algorithm reproduces volumes of symmetric and deformed in vitro objects accurately over a wide range of size and shape, and it produces repeatable left ventricular volumes in the clinical situation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0894-7317(14)80079-5DOI Listing

Publication Analysis

Top Keywords

left ventricular
16
ventricular volumes
12
+/- +/-
12
volumes
9
three-dimensional reconstruction
8
vitro accuracy
8
accuracy clinical
8
clinical repeatability
8
repeatability volumes
8
true volumes
8

Similar Publications

Data on outcomes of extracorporeal membrane oxygenation (ECMO) are limited in patients with pulmonary atresia intact ventricular septum (PAIVS). The objective of this study was to describe the use of ECMO and the associated outcomes in patients with PAIVS. We retrospectively reviewed neonates with PAIVS who received ECMO between 2009 and 2019 in 19 US hospitals affiliated with the Collaborative Research for the Pediatric Cardiac Intensive Care Society (CoRe-PCICS).

View Article and Find Full Text PDF

Aims: A cardiovascular magnetic resonance (CMR) approach to non-invasively estimate left ventricular (LV) filling pressure was recently developed and shown to correlate with invasively measured pulmonary capillary wedge pressure (PCWP). We examined the association between CMR-estimated PCWP (CMR-PCWP) and other imaging and biomarker measures of congestion, and the effect of empagliflozin on these, in the SUGAR-DM-HF trial (NCT03485092).

Methods And Results: SUGAR-DM-HF enrolled 105 patients with heart failure with reduced ejection fraction (HFrEF) and pre-diabetes or type 2 diabetes who were randomly assigned to empagliflozin 10 mg or placebo once daily for 36 weeks.

View Article and Find Full Text PDF

Physical activity improves myocardial structure, function and resilience via complex, incompletely defined mechanisms. We explored effects of 1-2 wks swim training on cardiac and systemic phenotype in young male C57Bl/6 mice. Two wks forced swimming (90 min twice daily) resulted in cardiac hypertrophy (22% increase in heart:body weight, P<0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!