Perchloroethylene exposure in 28 dry-cleaning establishments and in 25 homes occupied by dry cleaners in Modena, Italy, was investigated. Environmental air samples and alveolar air samples from dry cleaners (n = 60) and from their family members (n = 23) were collected. The degree of perchloroethylene on the dry-cleaning premises varied widely from establishment to establishment. Spot sampling ranged from 0.6 to 75 mg/m3, whereas sampling by personal passive dosimeters ranged from 2.6 to 221.5 mg/m3 (8-h time weighted average values). Perchloroethylene in alveolar air samples collected at the end of the work day correlated closely with the 8-h time weighted average values (r = .750, p = .001), and correlated also with alveolar air samples collected at home in the evening (r = .665, p = .001) and the following morning (r = .549, p < .001). Perchloroethylene levels inside the homes of dry cleaners appeared significantly higher than in 29 houses selected as controls (Mann Whitney U test, p < .001). Perchloroethylene in alveolar air samples collected at home suggests that nonoccupational exposure to perchloroethylene for family members of dry cleaners exists.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00039896.1994.9955005DOI Listing

Publication Analysis

Top Keywords

dry cleaners
20
air samples
20
alveolar air
16
family members
12
samples collected
12
exposure perchloroethylene
8
cleaners family
8
8-h time
8
time weighted
8
weighted average
8