Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Effective solid-phase extraction, derivatization, and GC/MS procedures are developed for the simultaneous determinations of butalbital, amobarbital, pentobarbital, and secobarbital, using a deuterated pentobarbital (d5-pentobarbital) as the internal standard. Buffered (pH 7) urine samples were extracted with Bond Elute Certify II cartridge. Iodomethane/tetramethylammonium hydroxide in dimethylsulfoxide was used for methylation, while a HP 5970 MSD equipped with a 13 m J & W DB-5 column (5% phenyl polysiloxane phase) and the Thru-Put Target software package were used for GC/MS analysis and data processing. This protocol was found to be superior, in both chromatographic performance characteristics and quantitation results, over a liquid-liquid extraction procedure without derivatization using hexobarbital as the internal standard. Extraction recoveries observed from control samples containing four barbiturates range from 80% to 90%. Good one-point calibration data are obtained for all four barbiturates in the 50 to 3200 ng/mL range. Interestingly, the one-point calibration data for pentobarbital are inferior to the other three barbiturates--due to interference from the internal standard (d5-pentobarbital). The calibration data of pentobarbital are best described by a hyperbolic curve regression model. Precision data (% CV) for GC/MS analysis, over-all procedure, and day-to-day performance are approximately 2.0%, 6.0%, and 8.0%, respectively. With the use of a 2 mL sample size, the attainable detection limit is approximately 20 ng/mL.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!