Since its introduction at the beginning of the 60s Dacron has proved to be a reliable and durable substitute for aortic reconstructions. It is however susceptible to late thrombosis, infection and aneurysmal dilatation in a significant number of cases. ePTFE vascular prosthesis, introduced in 1972, have proved to perform well for peripheral reconstructions and was used in aortoiliac position since 1980. In 1991 a new type of ePTFE rendered longitudinally extensible (Gore-Tex Stretch) was introduced into clinical practice. The aim of this study is to evaluate surgical performance, short term patency and interaction with periprosthetic tissues of Gore-Tex Stretch straight and bifurcated prosthesis. Between October 1991 and December 1993, 59 patients underwent aortic reconstruction at our Institution either for infrarenal aortic aneurysm (19 patients, 16 males, 3 females, mean age 68.8 +/- 8.5 years) or for aortoiliac occlusive disease (40 patients, 36 males, 4 females, mean age 60.5 +/- 7.2 years). Forty-eight bifurcated and eleven straight grafts were implanted using Gore-Tex sutures. Preoperative workup included Ultrasonography, Magnetic Resonance Imaging (MRI) in patients with aneurysms and Intra Arterial Digital Subtraction Arteriography (DSA) in patients with occlusive disease. Intraoperative parameters were recorded. Postoperative follow-up included ultrasonographic evaluation at 1st and 7th day, 15th postoperative week and at 3 monthly intervals; Intra Venous DSA before dismission and MRI at the 1st and 15th postoperative week. Intraoperatively the grafts proved to be soft and flexible with good handling and suturing characteristics. Perioperative bleeding was 480 +/- 299 ml for occlusive disease cases and 633 +/- 314 for aneurysm cases. No operative mortality was recorded.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source

Publication Analysis

Top Keywords

occlusive disease
12
magnetic resonance
8
resonance imaging
8
gore-tex stretch
8
patients males
8
males females
8
females age
8
+/- years
8
15th postoperative
8
postoperative week
8

Similar Publications

The guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements.

View Article and Find Full Text PDF

The Circle of Willis (CW) is a critical cerebrovascular structure that supports collateral blood flow to maintain brain perfusion and compensate for eventual occlusions. Increased tortuosity of highrisk vessels within the CW has been implicated as a marker in the progression of cerebrovascular diseases especially in structures like the internal carotid artery (ICA). This is partly due to age-related plaque deposition or arterial stiffening.

View Article and Find Full Text PDF

Background: The clinical manifestations of sickle cell disease (SCD) result in significant morbidity and healthcare costs. The effect of weather as a risk factor for the development of vaso-occlusive episodes (VOEs) has been previously studied, although with variable results. The aim of our retrospective, nationwide study was to determine the association between weather patterns and pediatric VOE and acute chest syndrome (ACS).

View Article and Find Full Text PDF

Whey Protein-Based Hydrogel Microspheres for Endovascular Embolization.

ACS Appl Bio Mater

January 2025

Department of Radiology, University of Minnesota, Minneapolis, Minnesota 55455, United States.

Transarterial embolization (TAE) is an image-guided, minimally invasive procedure for treating various clinical conditions by delivering embolic agents to occlude diseased arteries. Conventional embolic agents focus on vessel occlusion but can cause unintended long-term inflammation and ischemia in healthy tissues. Next-generation embolic agents must exhibit biocompatibility, biodegradability, and effective drug delivery, yet some degradable microspheres degrade too quickly, leading to the potential migration of fragments into distal blood vessels causing off-target embolization.

View Article and Find Full Text PDF

Introduction: Cerebral ischemic strokes cause brain damage, primarily through inflammatory factors. One of the regions most affected by middle cerebral artery occlusion (MCAO) is the hippocampus, specifically the CA1 area, which is highly susceptible to ischemia. Previous studies have demonstrated the anti-inflammatory properties of quercetin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!