The increase in body water during pregnancy is responsible for the largest portion of weight gain and is of interest of clinical practitioners. However, assessing changes in body fluids is not easily accomplished during pregnancy. The purpose of this study was to examine the accuracy of bioelectrical impedance spectroscopy for estimating fluid volumes before, during, and after pregnancy. Ten healthy adult women were recruited for the study. Total body water (TBW) and extracellular fluid (ECF) volume were measured at baseline (preconception); 8-10, 24-26, and 34-36 wk of gestation; and 4-6 wk postpartum by deuterium oxide and NaBr dilution, respectively. Estimates of TBW and ECF were also obtained by bioimpedance spectroscopy (BIS). At baseline, mean values for dilution and BIS estimates of TBW and ECF were 33.2 +/- 4.6 (SD) vs. 31.6 +/- 6.2 liters and 15.2 +/- 1.3 vs. 16.9 +/- 2.3 liters, respectively. TBW and ECF estimated by BIS were not significantly different from the dilution values at any time point. These results suggest that BIS may be useful in estimating volumes of ECF and TBW during pregnancy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/jappl.1995.78.3.1037 | DOI Listing |
J Cardiothorac Vasc Anesth
November 2024
Division of Cardiovascular and Thoracic Surgery, North Shore University Hospital, Northwell, New Hyde Park, NY. Electronic address:
Objective: To assess whether bioimpedance spectroscopy analysis (BIA) can be used as a tool to guide postoperative fluid management in patients undergoing cardiac surgery.
Design: An observational study.
Setting: A single tertiary hospital.
Life (Basel)
December 2023
First Department of Anaesthesiology and Intensive Therapy, Medical University Lublin, 20-954 Lublin, Poland.
Objective: To compare bioelectrical impedance analysis (BIA)-derived parameters in healthy volunteers and critically ill patients and to assess its prognostic value in an ICU patient cohort.
Design: Retrospective, observational data analysis.
Setting: Single centre, tertiary-level ICU (Ziekenhuis Netwerk Antwerpen, ZNA Stuivenberg Hospital).
Curr Pharm Biotechnol
July 2024
School of Pharmacy, Anhui University of Chinese Medicine, Hefei, 230012, PR China.
Background: Spleen deficiency-water dampness symptom is closely related to body fluid-mediated organism metabolism and circulation. However, previous clinical evaluation of spleen deficiency-water dampness model was based only on body weight, D-xylose excretion rate, serum gastrin content, etc. Therefore, we established a large sample of normal rats and model rats experiment to verify the scientific nature of bio-impedance measuring body fluid indexes for evaluation of the modeling state.
View Article and Find Full Text PDFMed Sci Sports Exerc
March 2024
School of Kinesiology and Nutrition, University of Southern Mississippi, Hattiesburg, MS.
Purpose: The purpose of this cross-sectional evaluation was to determine the associations between raw bioelectrical impedance and cardiometabolic health parameters in a sample of young non-Hispanic White and African American adults.
Methods: A total of 96 (female: 52, male: 44) non-Hispanic White ( n = 45) and African American adults ( n = 51) between the ages of 19 and 37 yr (22.7 ± 3.