Unlabelled: We developed a completely automatic technique to reorient transaxial images into short-axis (oblique) myocardial perfusion SPECT images.
Methods: The algorithm starts by isolating (segmenting) the left ventricle (LV) myocardium using a combination of iterative clusterification and rule-based location/size/shape criteria. The three-dimensional, mid-myocardial LV surface is initially estimated as the locus of the trilinearly interpolated maxima for the count profiles originating from the center of mass of the segmented LV. The final mid-myocardial surface is obtained by iteratively applying this process, incorporating additional constraints of shape and texture and using the nonsegmented, nonthresholded transaxial image to obtain information on hypoperfused areas of the myocardium. It is then fitted to an ellipsoid, of which the major axis is assumed to represent the long axis of the LV, and the three-dimensional image volume is resliced perpendicularly to it.
Results: The algorithm was retrospectively applied to 400 dual-isotope studies (200 rest 201TI, 200 stress 99mTc-sestamibi) from 200 consecutive patients. Segmentation was successful in 394/400 (98.5%) of the patients. The reproducibility of computer-based reorientation was perfect and significantly better than either intraobserver or interobserver reproducibility.
Conclusion: Automatic reorientation offers the potential for consistently faster and more accurate image processing and analysis and is an important step towards totally operator-less management of myocardial perfusion SPECT data.
Download full-text PDF |
Source |
---|
Crit Care
January 2025
División de Terapia Intensiva, Hospital Juan A. Fernández, Buenos Aires, Argentina.
The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.
View Article and Find Full Text PDFJ Nucl Med
January 2025
Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California;
Nuclear cardiology offers a diverse range of imaging tools that provide valuable insights into myocardial perfusion, inflammation, metabolism, neuroregulation, thrombosis, and microcalcification. These techniques are crucial not only for diagnosing and managing cardiovascular conditions but also for gaining pathophysiologic insights. Surrogate biomarkers in nuclear cardiology, represented by detectable imaging changes, correlate with disease processes or therapeutic responses and can serve as endpoints in clinical trials when they demonstrate a clear link with these processes.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
January 2025
Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shimmachi, Suita, Osaka, 564-8565, Japan.
Background: Non-response to cardiac resynchronization therapy (CRT) is an important issue in the treatment of heart failure with reduced ejection fraction (HFrEF) and non-left bundle branch block (LBBB). Electrocardiogram-gated myocardial perfusion single-photon emission computed tomography imaging (G-MPI SPECT) is typically used to assess left ventricular (LV) dyssynchrony. This study aimed to determine whether G-MPI parameters are associated with non-responsiveness to CRT.
View Article and Find Full Text PDFInt J Cardiol
December 2024
Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China; Cardiovascular Research Institute of Wuhan University, Wuhan, China; Hubei Key Laboratory of Cardiology, Wuhan, China. Electronic address:
Aims: Timely assessment of abnormal microvascular perfusion (MVP) may improve prognosis in patients with ST-segment elevation myocardial infarction (STEMI). This study aimed to determine the clinical implications of contrast-flow quantitative flow ratio (cQFR) in evaluating abnormal MVP and subsequent outcomes among STEMI patients after successful primary percutaneous coronary intervention (PPCI).
Methods: The study population consisted of 2 independent cohorts.
Am J Med
December 2024
University of Arizona, College of Medicine, Phoenix.
Background: Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant.
Methods: Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!