The use of vortex flow filtration for harvesting cells or conditioned medium from large scale bioreactors has proven to be an efficient, low shear method of cell concentration and conditioned medium clarification. Several 8-10 L batches of the human histiocytic lymphoma U-937 cell line (ATCC CRL 1593) were concentrated to less than 1 L by vortex flow filtration through a 3.0 microns membrane. An aggressive filtration regimen caused a 17% loss of cell viability and a 32% loss of IL-4 receptor binding capacity when compared to a batch centrifuged control. A reduction of the rotor speed from 1500 to 500 RPM and reduction of system back pressure from 10 to 0 PSIG resulted in cell viability and IL-4 binding capacity comparable to the control. Several 10 L batches of baculovirus infected Sf-9 cells were also concentrated to less than 1 L by vortex flow filtration through a 3.0 microns membrane. SDS-PAGE analysis of filtrate samples showed that aggressive filtration caused cell damage which led to contamination of the process stream by cellular lysate. When rotor speed was reduced to 500 RPM and system back pressure was reduced to 0 PSIG, the amount of contaminating lysate proteins in filtrate samples was comparable to a batch centrifuged control.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF00762400 | DOI Listing |
Comput Biol Med
January 2025
LaBS, Dipartimento di Chimica, Materiali e Ingegneria Chimica "Giulio Natta", Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy. Electronic address:
In the context of dynamic image-based computational fluid dynamics (DIB-CFD) modeling of cardiac system, the role of sub-valvular apparatus (chordae tendineae and papillary muscles) and the effects of different mitral valve (MV) opening/closure dynamics, have not been systemically determined. To provide a partial filling of this gap, in this study we performed DIB-CFD numerical experiments in the left ventricle, left atrium and aortic root, with the aim of highlighting the influence on the numerical results of two specific modeling scenarios: (i) the presence of the sub-valvular apparatus, consisting of chordae tendineae and papillary muscles; (ii) different MV dynamics models accounting for different use of leaflet reconstruction from imaging. This is performed for one healthy subject and one patient with mitral valve regurgitation.
View Article and Find Full Text PDFJ Environ Manage
January 2025
Department of Civil, Environmental and Architectural Engineering, University of Padova, Via Marzolo 9, 35131, Padova, Italy.
The materials removed in the oil separation units of wastewater treatment plants can be referred to as fat, oil and grease (FOG) waste. FOG waste accumulation in treatment plants can cause clogging of pipes, production of excessive scums and foams, and negatively affect air/liquid oxygen transfer. While conventional disposal routes of this material can be limited by its water and organic content, FOG can represent a source of bio-energy other than bio-diesel production.
View Article and Find Full Text PDFWater Res
January 2025
State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco- Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China. Electronic address:
The flow through the grit chamber is non-biochemically treated wastewater, which contains microorganisms mainly from the source of wastewater generation. There are limited reports on aerosol particles generated by grit chambers compared with those produced by biochemical treatment tanks. This study analyzed the fugitive characteristics of aerosol particles produced in grit chambers at nine wastewater treatment plants in three regions of China.
View Article and Find Full Text PDFDokl Biochem Biophys
January 2025
Bakulev National Medical Research Center for Cardiovascular Surgery, Moscow, Russia.
The study presents a numerical parametric investigation of flow structures in channels with a longitudinal-radial profile zR = Const and a spherical dome at the base. The goal of the study was to examine the flow structures in these channels depending on the exponent N of the profile and the height of the dome, to determine the conditions that provide optimal centripetal swirling flow, analogous to blood flow in the heart chambers and major vessels. The investigation was conducted using a comparative analysis of flow structures in channel configurations zR = Const, carried out in two stages.
View Article and Find Full Text PDFComput Methods Programs Biomed
January 2025
Department of Mechanics & Engineering, College of Architecture & Environment, Sichuan University, Chengdu 610065, China; Sichuan University Yibin Park / Yibin Istitute of Industrial Technology, Yibin 644000, China. Electronic address:
Objectives: As is well known, plaque morphology plays an important role in the hemodynamics of stenotic coronary arteries, thus their clinic outcomes. However, so far, there has been no research on how the cross-sectional shape of a stenotic lumen affects its hemodynamics. Therefore, this study aims to explore the impact of plaque cross-sectional shape on coronary hemodynamics under mild or moderate stenosis conditions (diameter stenosis degree ≤50 %).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!