An EMG-controlled grasping system for tetraplegics.

J Rehabil Res Dev

Miami Project, University of Miami School of Medicine, FL 33136, USA.

Published: February 1995

A two-channel, portable, battery operated, functional electrical stimulation (FES) system with surface electrodes to enhance grasping in tetraplegics was developed and tested. This system is meant for tetraplegics capable of grasping by tenodesis. Candidates for this system must retain some wrist extension, and have paralyzed but innervated finger flexors, and nearly normal shoulder and elbow coordination within the working space. The control signal that turns the stimulation of forearm finger and thumb flexors on and off is based on the detection of the threshold of the amplified, rectified, and integrated electromyographic recordings using surface electrodes positioned over the wrist extensors. The voluntary contraction of wrist extensors is suitable for triggering the stimulation, and it is reproducible enough for daily home use. The new device was tested on subjects with tetraplegia, and the general conclusions are: 1) the system increases the strength of the grasp: 2) no side effects or related problems were noticed: 3) the training period is short: 4) the reliability of the operation is good; and, 5) the design of the analog part of the system allows its easy integration into a computerized device. Functional tests of the system showed that some of the study subjects did not benefit from this approach due to disuse and denervation types of muscle atrophy of their finger flexors, lack of controllable wrist extension, curled resting position of distal and proximal interphalangeal (IP) joints, and/or inability to bring the thumb in the opposition of fingers.

Download full-text PDF

Source

Publication Analysis

Top Keywords

surface electrodes
8
wrist extension
8
finger flexors
8
wrist extensors
8
system
7
emg-controlled grasping
4
grasping system
4
system tetraplegics
4
tetraplegics two-channel
4
two-channel portable
4

Similar Publications

The preparation and modification of porous electrodes are an important component of the new generation electrochemical oxidation technology. Rapid preparation of porous electrodes can be easily achieved by synchronous oxygen bubble electrodeposition. However, according to the reaction mechanism of lead dioxide anodic electrodeposition, there is bound to be a competitive reaction of adsorbed hydroxyl radicals in the oxygen bubble template method, which means that synchronous OER impacts both the surface morphology and potentially the crystalline structure of the metal oxides.

View Article and Find Full Text PDF

Automated, rapid electrocatalyst discovery techniques that comprehensively address the exploration of chemical spaces, characterization of catalyst robustness, reproducibility, and translation of results to (flow) electrolysis operation are needed. Responding to the growing interest in biomass valorization, we studied the glycerol electro-oxidation reaction (GEOR) on gold in alkaline media as a model reaction to demonstrate the efficacy of such methodology introduced here. Our platform combines individually addressable electrode arrays with HardPotato, a Python application programming interface for potentiostat control, to automate electrochemical experiments and data analysis operations.

View Article and Find Full Text PDF

Wearable sensors are increasingly being used as biosensors for health monitoring. Current wearable devices are large, heavy, invasive, skin irritants, or not continuous. Miniaturization was chosen to address these issues, using a femtosecond laser-conversion technique to fabricate miniaturized laser-induced graphene (LIG) sensor arrays on and encapsulated within a polyimide substrate.

View Article and Find Full Text PDF

Flexible Eyelid Pressure and Motion Dual-Mode Sensor Using Electric Breakdown-Induced Piezoresistivity and Electrical Potential Sensing.

ACS Appl Mater Interfaces

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, Beijing 100730, China.

Multiple ocular surface disorders are associated with the mechanical properties of the interface between the eyelid and cornea. Determining eyelid pressure is vital for diagnosing and preventing these disorders. However, current measurements rely on flat piezoresistive pressure sensor arrays that lack eye-motion sensing capabilities, resulting in discomfort and measurement inaccuracies.

View Article and Find Full Text PDF

Realizing fast charging in high-specific-energy lithium metal batteries (LMBs) remains a significant challenge. Here, a oleophilic garnet suspension electrolyte design is reported, using inorganic solid electrolyte modified by low-surface-energy 1H,1H,2H,2H-perfluorooctyl trichlorosilane (PFOTS), to address the dilemma of fast charging and high specific energy in LMBs. With the oleophilic suspension electrolytes, the ionic conductivity of carbonate electrolyte is increased by ≈20%.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!