We have designed an automatic detector system for noninvasive monitoring of irrigating fluid absorption during transurethral resection of the prostate. Ethanol, which is used as a tracer for the fluid, is measured in the expired breath of the patient. The breath ethanol monitor can be used both in the awake patient and during general anaesthesia. A lap-top computer controls the monitor and calculates the fluid absorption 1-3 times per min and uses the pattern of ethanol changes to indicate whether the fluid is being taken by the intra- and/or extravascular route. The monitor has been used in routine operations for one year. The interpretation of absorption routes was checked by control methods or by evaluation of the postoperative breath-ethanol curve. We found the indicated absorption to be correct in all resections with absorption large enough for the monitor to present an interpretation.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2044.1995.tb04609.xDOI Listing

Publication Analysis

Top Keywords

fluid absorption
12
monitoring irrigating
8
irrigating fluid
8
absorption transurethral
8
absorption
6
fluid
5
continuous monitoring
4
transurethral surgery
4
surgery designed
4
designed automatic
4

Similar Publications

Purpose: To study choroidal thickness (CT) and luminal areas of choroidal vessels in the setting of fovea-off rhegmatogenous retinal detachment (RRD).

Methods: Twenty-seven eyes with RRD were prospectively studied before and after pars plana vitrectomy and SF6 tamponade, using swept-source optical coherence tomography (SS-OCT). CT was measured pre- and postoperatively both subfoveally and in attached macular areas.

View Article and Find Full Text PDF

Although significant progress has been made in the effective measurement of Zn(II), Аlizarin red S (ARS) was immobilized on polyethylene polyamine-modified polyacrylonitrile (PPF-1) via a new matrix. This approach allows the detection of low levels of Zn(II) ions in various water samples via preconcentrated atomic absorption spectrometry. The use of PPF-1 in a polymer matrix for zinc preconcentration presents several advantages over traditional sorbtion-spectroscopic methods, including reduced cost, high zinc recovery, increased sensitivity, and selectivity.

View Article and Find Full Text PDF

Bactericidal Hemostatic Sponge: A Point of Care Solution to Combat Traumatic Injury.

Adv Healthc Mater

January 2025

Antimicrobial Research Laboratory, New Chemistry Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Jakkur, Bengaluru, Karnataka, 560064, India.

Uncontrollable haemorrhage and associated microbial contamination in the battlefield and civilian injuries pose a tremendous threat to healthcare professionals. Such traumatic wounds often necessitate an effective point-of-care solution to prevent the consequent morbidity owing to blood loss or haemorrhage. However, developing superior hemostatic materials with anti-infective properties remains a challenge.

View Article and Find Full Text PDF

Paeoniflorin is a natural pharmaceutical ingredient with a widely biological activity. However, as a hydrophilic drug, the problem of low transdermal rate limits its clinical application. To overcome this shortage, LUVs were used as biocompatible carriers of paeoniflorin in this study.

View Article and Find Full Text PDF

Background And Objective: Coughing events are eruptive sources of virus-laden droplets/droplet nuclei. These increase the risk of infection in susceptible individuals during airborne transmission. The oral cavity functions as an exit route for exhaled droplets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!