The assessment of plutonium and americium in contaminated wounds with high energy resolution semiconductor detectors.

Appl Radiat Isot

Whole Body Counting, Nuclear Spectrometry and Policy support, Radiation protection, CEN.SCK, Mol, Belgium.

Published: March 1995

A simple to use method was installed for the measurement of wounds contaminated with plutonium and americium by using a semiconductor detector. This technique does not explicitly require the knowledge of the detector efficiency but uses a plant 241Am calibration source. A computer programme has also been developed for the quantification of the contamination according to the shape and the depth of the contaminant in the wound.