The results are presented from a consecutive operative series of 62 acoustic neuromas in 60 patients following the introduction of improved neurophysiological monitoring techniques. Twenty-two patients had usable preoperative hearing. Thirty tumours were less than 2.5 cm diameter and 32 greater in size. Operation was via a 3-4-cm diameter retromastoid craniectomy. The internal auditory meatus was opened by an ENT surgeon (RM) using a drill and the facial nerve identified by stimulation. The tumour was then centrally evacuated by a neurosurgeon (MT/HC) using an ultrasonic aspirator, and the thin exterior part of the tumour carefully dissected off the nerves in or around the capsule with constant stimulation and monitoring of facial EMG, BSAEP and electrocochleography. A new type of stimulation probe has been designed and coupled to a stimulator/integrator/tone burst generator (SB) so that continuous immediate direct feedback to the surgeon is possible. A variable amplitude discriminator rejects baseline EMG (> 50 microV) and a gating circuit prevents stimulus artefact (during monopolar stimulation) from causing interference. By these means the VII nerve could be identified even when translucent and undefinable as a nerve bundle. Anatomical preservation was possible in 98% of VII nerves. Full facial function was present in 20 cases immediately postoperatively. Full delayed recovery occurred in 23 cases giving an eventual total in House Grade I of 69%. Seven other cases recovered to House Grade II. There was therefore 81% satisfactory facial nerve function. This percentage is exactly the same for larger and for smaller tumours. Anatomical preservation of the VIII nerve was achieved in 24/62 (39%) of the whole series and 11/16 (69%) of those with a hearing loss of < 50 dB. Functional preservation of hearing described as usable by the patient (< 65 dB) was achieved in 7/22 cases (32%), 3/13 (23%) in tumours < 2.5 cm and 4/9 (44%) in those > 2.5 cm diameter. Hearing preservation of < 50 dB in patients with preoperative hearing threshold < 50 dB and tumours of < 2.5 cm was 3/11 (27%). Monitoring by BSAEP and ECochG was technically unsatisfactory because the responses were affected by drilling and stimulation. Acoustic nerve preservation should be attempted in all cases with measurable hearing, regardless of tumour size.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02688699409101179DOI Listing

Publication Analysis

Top Keywords

acoustic nerve
8
nerve preservation
8
acoustic neuromas
8
preoperative hearing
8
facial nerve
8
nerve identified
8
anatomical preservation
8
house grade
8
nerve
7
preservation
6

Similar Publications

 Many patients with neurofibromatosis type 2 (NF2) suffer from sensorineural hearing loss, and associated cochlear nerve compromise in NF2 patients makes auditory brainstem implant (ABI) an attractive treatment option. The long-term outcomes and benefits of the device are still being explored.  A retrospective review was conducted for 11 ABI recipients at a single-institution tertiary center between November 2017 and August 2022.

View Article and Find Full Text PDF

A CT Radiologic Assessment of the Incidence of Cochlear-Facial Dehiscence and the Thickness of Bone between the Cochlea and Facial Nerve among Normal Temporal Bones.

J Neurol Surg B Skull Base

February 2025

Department of Head and Neck Surgery, David Geffen School of Medicine, University of California, Los Angeles, California, CA 90095, United States.

Cochlear-facial dehiscence (CFD) is a relatively new diagnosis which occurs when the bony partition between the labyrinthine segment of the facial nerve and the cochlea is dehiscent. This is considered one of several third window lesions which produce varying degrees of auditory and vestibular symptoms. Imaging studies have identified a consistently higher incidence of CFD when compared with the only histopathologic study present in the literature.

View Article and Find Full Text PDF

 In the present study, we investigated the round window (RW) and neighboring anatomical structures using temporal computed tomography (CT) which are important for cochlear implant (CI) electrodes.  In this retrospective study, the temporal CT images of 112 adult patients (45 males and 67 females) were evaluated. We classified mastoid pneumatization, and measured RW diameter, RW-carotid canal (CC) distance, RW-facial nerve mastoid segment (FNMS) distance, RW-pyramidal eminence distance, RW-jugular bulb (JB) distance, and RW-internal acoustic canal (IAC) distance.

View Article and Find Full Text PDF

Background And Objectives: Jugular paragangliomas (JPG) pose a surgical challenge because of their vascularity and complex location. Stereotactic radiosurgery (SRS) offers a minimally invasive management for patients with JPG. Our aim was to evaluate outcomes of Gamma Knife radiosurgery (GKRS) for the treatment of JPG over the long term.

View Article and Find Full Text PDF

Machine-Learning Predictions of Cochlear Implant Functional Outcomes: A Systematic Review.

Ear Hear

January 2025

San Francisco Department of Otolaryngology - Head and Neck Surgery, University of California, San Francisco, California, USA.

Objectives: Cochlear implant (CI) user functional outcomes are challenging to predict because of the variability in individual anatomy, neural health, CI device characteristics, and linguistic and listening experience. Machine learning (ML) techniques are uniquely poised for this predictive challenge because they can analyze nonlinear interactions using large amounts of multidimensional data. The objective of this article is to systematically review the literature regarding ML models that predict functional CI outcomes, defined as sound perception and production.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!