We studied pulmonary haemodynamics at rest and on exercise in 44 consecutive patients with moderate to severe obstructive sleep apnea (OSA), mean AHI > 40. The diagnosis was confirmed by standard polysomnography (PSG). According to history and results of spirometric measurements patients were divided to two groups, pure OSA and OSA complicating chronic obstructive pulmonary disease (overlap syndrome). In 34 pts with OSA (31 M, 3 F), means: age 45 +/- 8 years, body weight 108 +/- 22 kg, BMI49, VC 107 +/- 16% of N, FEV1 101 +/- 15% of N, PaO2 71 +/- 10 mmHg, PaCO2 39 +/- 3 mmHg, PSG showed AHI 66 +/- 15. Pulmonary haemodynamics at rest were within normal limits: PPA 16 +/- 5 mmHg, PW 7 +/- 3 mmHg, CO 4.5 +/- 1.5 l/min, PVR 184 +/- 92 dyne.s.cm-5. On low grade exercise (40 W) PPA increased to 31 +/- 10 mmHg, Pw to 12 +/- 6 mmHg and CO to 8.6 +/- 4.0 l/min, PVR remained unchanged. In eight pts abnormal rise in PPA on exercise resulted from the increase in driving pressure (PPA-Pw). In 2 pts it was due to abnormal increase in wedge pressure. In ten male pts presenting with COPD means: age 53 +/- 8 y, body weight 109 +/- 11 kg, BMI49, VC 53 +/- 14% of N, FEV1 36 +/- 16% of N, PaO2 57 +/- 10 mmHg, PaCO2 47 +/- 7 mmHg, PSG showed AHI 63 +/- 20. All pts presented with pulmonary hypertension (PH) at rest, PPA ranging from 21 to 37 mmHg, mean 26 +/- 5 mmHg. We conclude that patients with OSA have normal PPA at rest, 1/2 of them have PH on exercise due to restriction of pulmonary arterial bed and/or left ventricle dysfunction. Pts with overlap syndrome have moderate resting PH resulting from alveolar hypoxia.

Download full-text PDF

Source

Publication Analysis

Top Keywords

+/- mmhg
36
+/-
22
mmhg +/-
20
mmhg
10
obstructive sleep
8
sleep apnea
8
pulmonary haemodynamics
8
haemodynamics rest
8
overlap syndrome
8
age +/-
8

Similar Publications

Impact of Norepinephrine Use on Free Flap Survival in Breast Reconstructive Microsurgery.

Microsurgery

January 2025

Service de Chirurgie Plastique et Reconstructrice, Hôpital européen Georges-Pompidou, Paris, France.

Objective: The optimal method for maintaining intraoperative blood pressure during microsurgical procedures remains controversial. While intravenous fluid administration is essential, overfilling can lead to complications. Vasopressor agents are used cautiously due to their vasoconstrictive effects, which could potentially lead to flap failure.

View Article and Find Full Text PDF

Background: Intrabdominal pressure (IAP) is an important parameter. Elevated IAP can reduce visceral perfusion, lead to intraabdominal hypertension, and result in life-threatening abdominal compartment syndrome. While ingestible capsular devices have been used for various abdominal diagnoses, their application in continuous IAP monitoring remains unproven.

View Article and Find Full Text PDF

Noninvasive methods for intracranial pressure (ICP) monitoring have emerged, but none has successfully replaced invasive techniques. This observational study developed and tested a machine learning (ML) model to estimate ICP using waveforms from a cranial extensometer device (brain4care [B4C] System). The model explored multiple waveform parameters to optimize mean ICP estimation.

View Article and Find Full Text PDF

Background: To report clinical outcomes from a single-center cohort undergoing PAUL® Glaucoma Implant (PGI) surgery for secondary glaucoma after vitreoretinal surgery (VR).

Methods: Retrospective review of patients undergoing PGI surgery at the University Eye Hospital Bonn, Germany, from 04/2021 to 05/2023.

Results: 33 eyes of 33 patients were included.

View Article and Find Full Text PDF

Purpose: To evaluate the effect of osilodrostat and hypercortisolism control on blood pressure (BP) and glycemic control in patients with Cushing's disease.

Methods: Pooled analysis of two Phase III osilodrostat studies (LINC 3 and LINC 4), both comprising a 48-week core phase and an optional open-label extension. Changes from baseline in systolic and diastolic BP (SBP and DBP), fasting plasma glucose (FPG), and glycated hemoglobin (HbA) were evaluated during osilodrostat treatment in patients with/without hypertension or diabetes at baseline.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!