Object: To compare prospectively high resolution fast spin echo T2 weighted (FSE-T2W) images and gadolinium-enhanced spin echo T1 weighted images for diagnosis of pathology of the internal auditory meatus (IAM).

Patients And Methods: 114 patients underwent MR imaging at 1.5 T with the following protocol: axial images; whole brain FSE-T2W sequence (256 matrix); 2 sequences focused on IAM with high resolution FSE-T2W acquisitions (512 matrix, 3 mm sections with 1.5 mm overlapping); pre and postcontrast T1 weighted sequences focused on IAM. Examinations were viewed by senior neuroradiologists.

Results: 31 lesions were detected in the IAM by high resolution FSE-T2W images; 25 lesions were found in the IAM by postcontrast T1 weighted images, i.e. 6 false-positive results and none false-negative. On the basis of 228 studied IAMs the sensitivity, specificity and negative predictive value of this high resolution FSE-T2W sequence were 100%, 97% and 100% respectively.

Conclusion: Gadolinium enhanced sequence is not indispensable if high resolution FSE-T2W images are normal. Gadolinium-enhanced sequence remains essential in others equivocal cases (difficult diagnosis or abnormal IAM).

Download full-text PDF

Source

Publication Analysis

Top Keywords

high resolution
20
resolution fse-t2w
16
fse-t2w images
12
internal auditory
8
auditory meatus
8
spin echo
8
echo weighted
8
weighted images
8
fse-t2w sequence
8
sequences focused
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?