The effect of glucose on kinetics and the voltage-dependent characteristics of glucose-sensitive channels in hippocampal neurons were examined with the cell-attached mode of the patch-clamp technique. Recordings of a 100-pS K+ channel in the presence or absence of glucose demonstrate that the increase in channel open state probability (Po) induced by glucose deprivation (40- to 400-times the control in high-glucose medium) was largely due to a decrease in the global amount of time spent by the channel in a long-lived closed state. The Po value of the same 100-pS channel was also found to increase (by approx. 80-times) following a depolarization of 40 mV from rest, the main factor responsible for this being a dramatic shortening of the long closed-times on depolarization. Another glucose-sensitive channel of smaller conductance (approx. 10 pS) showed a similar dependence of Po on glucose, but different dependence on voltage, with long openings at the same hyperpolarized potentials where the 100-pS channel was almost always closed. Our results indicate that the action of glucose on the kinetics of hippocampal channels closely resembles that of ATP-sensitive channels in pancreatic beta-cells. Furthermore, they indicate that the two types of glucose-sensitive channels found in hippocampal neurons, differing not only in their single-channel conductance but also in the dependence on voltage, could play different roles in the responses of these cells to modified energetic supply.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF02584030DOI Listing

Publication Analysis

Top Keywords

100-ps channel
12
dependence glucose
8
glucose kinetics
8
glucose-sensitive channels
8
channels hippocampal
8
hippocampal neurons
8
dependence voltage
8
glucose
6
channel
6
channels
5

Similar Publications

The structure and spin of photoexcited Fe(phen) in water are examined by x-ray scattering and x-ray emission spectroscopy with 100 ps time resolution. Excitation of the low-spin (LS) ground state (GS) to the charge transfer state MLCT leads to the formation of a high-spin (HS) state that returns to the GS in 725 ps. Density functional theory (DFT) predicts a Fe-N bond elongation in HS by 0.

View Article and Find Full Text PDF
Article Synopsis
  • Space time frequency transfer is essential for technologies like optical clock networks, navigation, and quantum communication in space.
  • A new high-precision scheme using a simple laser communication system has been proposed, achieving effective time synchronization with minimal bandwidth usage (0.2%).
  • Experimental results over 113 km show impressive long-term stability and minimal time drift, laying the groundwork for advanced space communication links in the future.
View Article and Find Full Text PDF

We report on LinoSPAD2, a single-photon camera system, comprising a 512×1 single-photon avalanche diode (SPAD) front-end and one or two FPGA-based back-ends. Digital signals generated by the SPADs are processed by the FPGA in real time, whereas the FPGA offers full reconfigurability at a very high level of granularity both in time and space domains. The LinoSPAD2 camera system can process 512 SPADs simultaneously through 256 channels, duplicated on each FPGA-based back-end, with a bank of 64 time-to-digital converters (TDCs) operating at 133 MSa/s, whereas each TDC has a time resolution of 20 ps (LSB).

View Article and Find Full Text PDF

16-channel SiPM high-frequency readout with time-over-threshold discrimination for ultrafast time-of-flight applications.

EJNMMI Phys

December 2023

Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany.

Background: Over the past five years, ultrafast high-frequency (HF) readout concepts have advanced the timing performance of silicon photomultipliers (SiPMs). The shown impact in time-of-flight (TOF) techniques can further push the limits in light detection and ranging (LiDAR), time-of-flight positron-emission tomography (TOF-PET), time-of-flight computed tomography (TOF-CT) or high-energy physics (HEP). However, upscaling these electronics to a system-applicable, multi-channel readout, has remained a challenging task, posed by the use of discrete components and a high power consumption.

View Article and Find Full Text PDF

A time-based double-sided readout concept of 100 mm LYSO:Ce,Ca fibres for future axial TOF-PET.

EJNMMI Phys

July 2023

Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.

Background: Positron emission tomography (PET) requires a high signal-to-noise ratio (SNR) to improve image quality, with time-of-flight (TOF) being an effective way to boost the SNR. However, the scanner sensitivity and resolution must be maintained. The use of axially aligned 100-mm LYSO:Ce,Ca scintillation crystals with double-sided readout has the potential of ground-breaking TOF and sensitivity, while reducing parallax errors through depth-of-interaction (DOI) estimation, and also allowing a reduction in the number of readout channels required, resulting in cost benefits.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!