The effect of glucose on kinetics and the voltage-dependent characteristics of glucose-sensitive channels in hippocampal neurons were examined with the cell-attached mode of the patch-clamp technique. Recordings of a 100-pS K+ channel in the presence or absence of glucose demonstrate that the increase in channel open state probability (Po) induced by glucose deprivation (40- to 400-times the control in high-glucose medium) was largely due to a decrease in the global amount of time spent by the channel in a long-lived closed state. The Po value of the same 100-pS channel was also found to increase (by approx. 80-times) following a depolarization of 40 mV from rest, the main factor responsible for this being a dramatic shortening of the long closed-times on depolarization. Another glucose-sensitive channel of smaller conductance (approx. 10 pS) showed a similar dependence of Po on glucose, but different dependence on voltage, with long openings at the same hyperpolarized potentials where the 100-pS channel was almost always closed. Our results indicate that the action of glucose on the kinetics of hippocampal channels closely resembles that of ATP-sensitive channels in pancreatic beta-cells. Furthermore, they indicate that the two types of glucose-sensitive channels found in hippocampal neurons, differing not only in their single-channel conductance but also in the dependence on voltage, could play different roles in the responses of these cells to modified energetic supply.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF02584030 | DOI Listing |
Struct Dyn
September 2024
European Synchrotron Radiation Facility, CS 40220 Grenoble Cédex 9, France.
The structure and spin of photoexcited Fe(phen) in water are examined by x-ray scattering and x-ray emission spectroscopy with 100 ps time resolution. Excitation of the low-spin (LS) ground state (GS) to the charge transfer state MLCT leads to the formation of a high-spin (HS) state that returns to the GS in 725 ps. Density functional theory (DFT) predicts a Fe-N bond elongation in HS by 0.
View Article and Find Full Text PDFWe report on LinoSPAD2, a single-photon camera system, comprising a 512×1 single-photon avalanche diode (SPAD) front-end and one or two FPGA-based back-ends. Digital signals generated by the SPADs are processed by the FPGA in real time, whereas the FPGA offers full reconfigurability at a very high level of granularity both in time and space domains. The LinoSPAD2 camera system can process 512 SPADs simultaneously through 256 channels, duplicated on each FPGA-based back-end, with a bank of 64 time-to-digital converters (TDCs) operating at 133 MSa/s, whereas each TDC has a time resolution of 20 ps (LSB).
View Article and Find Full Text PDFEJNMMI Phys
December 2023
Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany.
Background: Over the past five years, ultrafast high-frequency (HF) readout concepts have advanced the timing performance of silicon photomultipliers (SiPMs). The shown impact in time-of-flight (TOF) techniques can further push the limits in light detection and ranging (LiDAR), time-of-flight positron-emission tomography (TOF-PET), time-of-flight computed tomography (TOF-CT) or high-energy physics (HEP). However, upscaling these electronics to a system-applicable, multi-channel readout, has remained a challenging task, posed by the use of discrete components and a high power consumption.
View Article and Find Full Text PDFEJNMMI Phys
July 2023
Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.
Background: Positron emission tomography (PET) requires a high signal-to-noise ratio (SNR) to improve image quality, with time-of-flight (TOF) being an effective way to boost the SNR. However, the scanner sensitivity and resolution must be maintained. The use of axially aligned 100-mm LYSO:Ce,Ca scintillation crystals with double-sided readout has the potential of ground-breaking TOF and sensitivity, while reducing parallax errors through depth-of-interaction (DOI) estimation, and also allowing a reduction in the number of readout channels required, resulting in cost benefits.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!