Coronary artery disease may be difficult to detect in diabetic patients. This study was designed to determine the specificity and sensitivity of three noninvasive tests. Accordingly, the results of 48-h ambulatory electrocardiogram (ECG) monitoring, maximal ECG exercise test, and intravenous dipyridamole myocardial thallium scintigraphy were compared in 59 middle-aged diabetic patients who were consecutively selected for suspected coronary artery disease. All patients also underwent coronary angiography, which was performed regardless of the results of the non-invasive tests. Twenty patients (34%) had significant coronary lesions, i.e. stenosis equal to or greater than 70%, and 16 of these 20 patients (80%) had double or triple vessel disease. Sensitivity and specificity were, respectively, 25% and 88% for ambulatory ECG monitoring, 75% and 77% for the exercise test and 80% and 87% for thallium myocardial scintigraphy. This observation strongly supports the use of non-invasive tests for the detection of coronary artery disease in those diabetic patients at high risk of such disease. As the exercise test is cheaper and more widely available than thallium myocardial scintigraphy it should be used as a first line examination. Dipyridamole myocardial scintigraphy may provide an alternative solution for those patients who cannot perform maximal exercise, or with atypical clinical presentation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF00401847 | DOI Listing |
Med Biol Eng Comput
January 2025
Faculty of Computing, Harbin Institute of Technology, Harbin, 150001, China.
The lumen centerline of the coronary artery allows vessel reconstruction used to detect stenoses and plaques. Discrete-action-based centerline extraction methods suffer from artifacts and plaques. This study aimed to develop a continuous-action-based method which performs more effectively in cases involving artifacts or plaques.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia, USA.
Patients with type 2 diabetes mellitus (DM) are more susceptible to microvascular complications. However, whether DM is associated with coronary microvascular dysfunction (CMD) is unclear. This observational study used data from the Coronary Microvascular Disease Registry (CMDR) (NCT05960474) and included patients with angina and no obstructive coronary artery disease (ANOCA) who underwent invasive CMD evaluation using the CoroVentis CoroFlow System (Abbott Vascular, Santa Clara, CA).
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada.
We present an 18-year-old male with Fallot's tetralogy (ToF) repaired with a transannular and main pulmonary artery (PA) patch, who suffered an acute coronary artery compression after a Harmony-TPV deployment. Left main coronary artery compression was confirmed with angiography and IVUS. He underwent emergent surgery, with a bioprosthetic valve replacement.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Pediatrics, Division of Cardiology, The Children's Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, Pennsylvania, USA.
Background And Aims: Drug-eluting stents (DES) are not designed for overexpansion to supra-nominal diameters or intentional stent fracture (ISF). The optimal dilation technique to minimize stent shortening (SS) and achieve ISF to accommodate pediatric somatic growth has not been described.
Methods: Three sizes of two commonly used DES were implanted within a silicone model to simulate blood vessels.
Interdiscip Cardiovasc Thorac Surg
January 2025
Department of Cardiovascular Surgery, Shiga University of Medical Science, Setatsukinowa, Otsu, Shiga, 520-2192, Japan.
Objectives: End-to-side anastomosis is common in coronary artery bypass grafting, although restrictive suturing can narrow the anastomosis. We evaluated ex vivo end-to-side models by numerically simulating fluid dynamics to compare various degrees of stenotic anastomoses to predict haemodynamic effects.
Methods: A carotid artery was grafted via an end-to-side anastomosis onto the left anterior descending artery of a porcine heart, with liquid silicone injected into the vessels.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!