A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of graft rotation on attachment site separation distances in anterior cruciate ligament reconstruction. | LitMetric

We created a model to see if twisting the graft in an anterior cruciate ligament reconstruction affected the distance separating the femoral and tibial attachments of the perimeter fibers of a patellar tendon graft. Graft bone plugs were simulated by two 12.5-mm diameter Delrin cylinders. Holes, 1 mm in diameter, were placed at the four corners of a centralized rectangle measuring 5 by 10 mm. Graft ligament fibers were represented by color-coded sutures passed through the holes in the modeled bone plugs. This graft model was fixed in tunnels reamed under arthroscopic guidance at the anterior cruciate ligament attachment sites of the femur and tibia in six fresh-frozen knee specimens. Spring gauges were used to measure indirectly the changes in distance of separation during knee flexion between the femoral and tibial attachments relative to a zero defined at 90 degrees of knee flexion. The tibial cylinder was rotated at 45 degrees increments from 90 degrees external to 180 degrees internal rotation relative to the femoral cylinder and measurements were repeated after each incremental rotation. External rotation resulted in a statistically significant higher mean separation distance (4.5 mm) for peripheral graft attachments than internal rotation (2.8 mm) (P = 0.05).

Download full-text PDF

Source
http://dx.doi.org/10.1177/036354659502300305DOI Listing

Publication Analysis

Top Keywords

anterior cruciate
12
cruciate ligament
12
ligament reconstruction
8
femoral tibial
8
tibial attachments
8
bone plugs
8
knee flexion
8
internal rotation
8
graft
6
rotation
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!