In this study an apparatus is described that will open and close a hinged section of a removable partial denture. A metal framework based on a "swinglock" type of hinge and latch design was constructed. An electric motor provided the drive for the opening and closing mechanism, which when operated set the device in motion. The device and results of a test run of 12,000 opening and closing operations are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0022-3913(05)80079-4DOI Listing

Publication Analysis

Top Keywords

removable partial
8
opening closing
8
locking endurance
4
endurance test
4
test hinged
4
hinged sections
4
sections removable
4
partial dentures
4
dentures study
4
study apparatus
4

Similar Publications

Purpose: To evaluate the effects of various beverages on surface roughness and microhardness of PEEK and PEKK polymers.

Methods: Rectangular-shaped PEEK and PEKK polymers were fabricated and examined in the study. The specimens were immersed for 28 days at 37°C in red wine, coffee, and distilled water.

View Article and Find Full Text PDF

Functional rehabilitation in patients with hemimandibulectomy remains a challenge no matter what method of reconstruction is chosen by physicians. In this paper, we aim to evaluate the feasibility of an acceptable occlusal restoration in patients who have undergone hemimanidublectomy without the reestablishment of mandibular continuity. Data were collected retrospectively on 10 patients with varying degrees of mandible resection.

View Article and Find Full Text PDF

Statement Of The Problem: Previous longitudinal studies have found that patients with shortened dental arches (SDA) have a higher risk of long-term tooth loss than complete dental arch (CDA). However, the difference between SDA and CDA concerning oral function has yet to be demonstrated.

Purpose: We aimed to clarify the influence of molar occlusal support on oral function in SDA and CDA participants cross-sectionally and longitudinally.

View Article and Find Full Text PDF
Article Synopsis
  • This study reviews the current applications, limitations, and challenges of using polyetheretherketone (PEEK) in stomatology, highlighting its importance in various dental procedures.
  • Numerous studies underscore PEEK's beneficial properties, such as biocompatibility and fracture resistance, and its use in many dental applications, including implants and orthodontic devices.
  • Despite its potential, most evidence is based on short-term studies, indicating a need for more long-term clinical research to fully support PEEK's effectiveness in dentistry.
View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess how wall thickness impacts the fracture load of 3D printed hollow zirconia teeth.
  • Different wall thicknesses (0.30, 0.50, 0.75, and 1.00 mm) were tested, with results showing that thicker walls (≥0.75 mm) had a greater fracture resistance.
  • Filling hollow teeth with resin significantly improved their strength, especially in thinner designs, highlighting the importance of wall thickness and material in dental applications.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!