Objective: To study the effect of sampling rate on the accuracy of fetal heart rate recording in labour.

Design: Prospective observational study.

Methods And Subjects: The fetal heart rate was obtained from 153 fetuses in labour. The heart rate data was sampled at a rate of 0.5 Hz (every 2 s) and the means and standard deviations of 5-min segments compared against the mean and standard deviation for all beats in the same time interval.

Results: There was a highly significant correlation between the means (r = 0.994, p < 0.001) and standard deviations (r = 0.957, p < 0.001) of FHR sampled on successive beats compared with 2 s sampling.

Conclusion: Two second sampling of the fetal heart rate in labour will allow a highly complex analytical algorithm to process the signal in near real time for objective analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0028-2243(94)02033-bDOI Listing

Publication Analysis

Top Keywords

heart rate
20
fetal heart
16
rate
8
sampling rate
8
standard deviations
8
heart
5
computerised fetal
4
rate analysis
4
analysis labour--effect
4
labour--effect sampling
4

Similar Publications

The study was designed to investigate the pattern of intraventricular Hemo-Dynamic Forces (HDF) and myocardial performance during exercise in Elite Cyclists (EC). Transthoracic stress echocardiography was performed on nineteen EC and thirteen age-matched sedentary controls (SC) at three incremental exercise intensities based on Heart Rate Reserve (HRR). Left Ventricular (LV) HDF were computed from echocardiography long-axis data sets using a novel technique based on endocardial boundary tracking, both in apex-base and latero-septal directions.

View Article and Find Full Text PDF

Outcomes of a transapical edge-to-edge repair system in secondary mitral regurgitation.

J Invasive Cardiol

January 2025

Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, China; State Key Laboratory of Cardiovascular Diseases, Zhongshan Hospital, Fudan University; NHC Key Laboratory of Ischemic Heart Diseases; Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences; National Clinical Research Center for Interventional Medicine, Shanghai, China.

Objectives: The ValveClamp system (Hanyu Medical Technology) is a novel transcatheter edge-to-edge repair (TEER) system designed for ease of operation; however, there is a lack of data on its application in secondary mitral regurgitation (SMR). The authors report the mid-term outcomes of TEER using the ValveClamp system in SMR.

Methods: The study prospectively analyzed consecutive severe SMR patients who underwent transapical ValveClamp implantation at 10 Chinese centers.

View Article and Find Full Text PDF

Objectives: The aim of this study was to determine the indication and optimal timing for performing a hemiarch procedure in patients undergoing valve-sparing root replacement (VSRR).

Methods: We conducted a retrospective study on 986 patients undergoing VSRR at three tertiary care centres. Inclusion criteria were all patients undergoing elective VSRR.

View Article and Find Full Text PDF

Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.

View Article and Find Full Text PDF

Background: The prompt and accurate identification of mild cognitive impairment (MCI) is crucial for preventing its progression into more severe neurodegenerative diseases. However, current diagnostic solutions, such as biomarkers and cognitive screening tests, prove costly, time-consuming, and invasive, hindering patient compliance and the accessibility of these tests. Therefore, exploring a more cost-effective, efficient, and noninvasive method to aid clinicians in detecting MCI is necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!