Advantages of continuous measurement of cardiac output 24 h a day.

Am J Physiol

Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson 39216-4505, USA.

Published: August 1995

To test the hypothesis that continuous measurement of cardiac output 24 h a day would provide a better day-by-day reproducibility of the daily average cardiac output than acute measurements, we developed a computer-assisted method to monitor cardiac output continuously using an electromagnetic flow transducer. Because the diastolic aortic flow, which is used as a zero-flow reference, can drift significantly with electromagnetic flow probes, automatic tracking of the diastolic flow baseline was considered essential for long-term measurements. To accomplish this, the analog pulsatile flow signal was digitally converted and processed by an IBM PC to correct for signal drift on a beat-per-beat basis. Using this computerized system in 19 chronically instrumented dogs, we compared the values of cardiac output during 5 consecutive control days, measured either for 20 h each day (allowed 4 h for special care) or for 30 min in the morning when the trained dogs were required to lie quietly in their cages. The results show that the coefficient of variation of the five daily averages in cardiac output for each individual dog was three times smaller when cardiac output was measured 20 h each day (2.9 +/- 0.3 vs. 9.7 +/- 1.0%). Whole-day coefficients of variation were also smaller for mean arterial pressure, heart rate, stroke volume, and total peripheral resistance. Because of this greater day-by-day reproducibility, continuous monitoring of cardiac output is likely to be more sensitive to small changes in cardiac output induced by experimental protocols.

Download full-text PDF

Source
http://dx.doi.org/10.1152/ajpheart.1995.269.2.H696DOI Listing

Publication Analysis

Top Keywords

cardiac output
36
cardiac
9
output
9
continuous measurement
8
measurement cardiac
8
output day
8
day-by-day reproducibility
8
electromagnetic flow
8
measured day
8
flow
5

Similar Publications

Introduction: Cardiac amyloidosis typically causes restrictive cardiomyopathy, in which the impairment of diastolic function is dominant. Echocardiography provides prognostic information through some important parameters: left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS). However, LVEF often remains preserved despite disease progression, and GLS is not routinely performed as it is limited by suboptimal image quality.

View Article and Find Full Text PDF

Background: The angiotensin-converting enzyme (ACE) insertion/deletion (I/D) polymorphism (rs4340) is associated with the pathogenesis of heart failure (HF). This polymorphism may contribute to a greater propensity for severe HF and excess weight.

Objective: To evaluate adiposity, cardiac function, and their association with ACE I/D polymorphism in HF patients.

View Article and Find Full Text PDF

Effects of Variable Ventilation on Gas Exchange in an Experimental Model of Capnoperitoneum: A Randomized Crossover Study.

Anesth Analg

January 2025

From the Unit for Anaesthesiological Investigations, Department of Anaesthesiology, Pharmacology, Intensive Care and Emergency Medicine, University of Geneva, Geneva, Switzerland.

Background: The rapid advancement of minimally invasive surgical techniques has made laparoscopy a preferred alternative because it reduces postoperative complications. However, inflating the peritoneum with CO2 causes a cranial shift of the diaphragm decreasing lung volume and impairing gas exchange. Additionally, CO2 absorption increases blood CO2 levels, further complicating mechanical ventilation when the lung function is already compromised.

View Article and Find Full Text PDF

Capillary refill time paradoxically decreases in a blood loss shock model.

Intensive Care Med Exp

January 2025

Department of Emergency Medicine in Linköping, and Department of Biomedical and Clinical Sciences, Linköping University, 582 25, Linköping, Sweden.

Background: This study aimed to investigate whether changes in capillary refill (CR) time precede macrovascular signs of deterioration in a human model of blood loss shock. The study was conducted at the Department of Emergency Medicine in Linköping, Sweden, and involved 42 healthy volunteers aged 18-45. Participants were randomized into two provocations of applied lower body negative pressure (LBNP): a stepwise escalation protocol and a direct application protocol, to simulate gradual and acute blood loss.

View Article and Find Full Text PDF

Background: Immune checkpoint inhibitors (ICIs) are effective antineoplastic agents but can cause adverse effects in many organ systems. Cardiovascular toxicities include arrhythmias, myocarditis, heart failure, takotsubo syndrome, pericarditis, coronary artery disease, and vasculitis.

Case Summary: A 66-year-old woman with Stage 3C2 endometrial carcinoma presented for her second cycle of pembrolizumab, carboplatin, and paclitaxel.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!