Endoscopes are used widely for the diagnosis and therapy of medical disorders. To prevent spread of nosocomial infection, all endoscopes should undergo thorough cleaning and high-level disinfection following each use. The Food and Drug Administration (FDA) has approved a user-friendly package label for one liquid chemical germicide that requires a 45-minute immersion at 25 degrees C to support a high-level disinfection label claim. Scientific data reviewed here suggest that one can achieve at least an 8-log reduction in M tuberculosis contamination with cleaning (4 logs) followed by chemical disinfection for 20 minutes (4 to 6 logs). The FDA should modify the label to state that if cleaning is accomplished using a standardized cleaning protocol, then a 20-minute immersion at 20 degrees C will be sufficient to achieve high-level disinfection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1086/647095 | DOI Listing |
GMS Hyg Infect Control
December 2024
Uzun Mehmet Chest and Work Diseases Hospital, Medical Microbiology Dept, Zonguldak, Turkey.
Background: The use of laryngeal masks (LM) has increased widely today, both in anesthesia and in emergency cases. LM are available as reusable and disposable. Although reuse of disposable LM is not recommended, they are reused again after decontamination with different methods in anesthesia units in some countries.
View Article and Find Full Text PDFJ Appl Microbiol
January 2025
Centre for Sustainable Disinfection and Sterilization, Technological University of the Shannon, Athlone Campus, N37 HD68, Ireland.
This is a timely and important review that focuses on the appropriateness of established cleaning, disinfection and sterilization methods to safely and effectively address infectious fungal drug-resistant pathogens that can potentially contaminate reusable medical devices used in healthcare environment in order to mitigate the risk of patient infection. The release of the World Health Organisation (WHO) fungal priority pathogen list (FPPL) in 2022 highlighted the public health crisis of antimicrobial resistance (AMR) in clinically relevant fungal species. Contamination of medical devices with drug-resistant fungal pathogens (including those on the FPPL) in healthcare are rare events that are more likely to occur due to cross-transmission arising from lapses in hand-hygiene practices.
View Article and Find Full Text PDFHealthcare (Basel)
December 2024
King Abdullah International Medical Research Center, Riyadh 11481, Saudi Arabia.
: Infection prevention and control (IPC) is essential to ensure the safety of dental personnel and patients. This study aimed to assess the knowledge and compliance of dental undergraduate students, interns, and postgraduate students with IPC measures in prosthodontic procedures. : A cross-sectional observational study was conducted at the College of Dentistry, King Saud bin Abdulaziz University for Health Sciences, involving 216 participants selected using stratified random sampling.
View Article and Find Full Text PDFAustralas J Ultrasound Med
November 2024
Introduction/purpose: There are varying international recommendations regarding the minimum level of disinfection required for ultrasound transducers used in percutaneous procedures. While some guidelines recommend high-level disinfection (HLD), others question the additional benefit this delivers over low-level disinfection (LLD).
Methods: This narrative review identifies current guidelines and evaluates the evidence used to support disinfection recommendations for ultrasound transducers used in percutaneous procedures.
Laryngoscope
December 2024
Department of Anesthesiology, University of California San Francisco, San Francisco, California, U.S.A.
Introduction: There is increasing prevalence of single-use flexible laryngoscopes in Otolaryngology. This study aims to quantify and compare the environmental outcomes of single-use disposable flexible laryngoscopes (SUD-Ls) and reusable flexible laryngoscope (R-Ls).
Methods: The ISO 14040 standardized Life Cycle Assessment (LCAs) was utilized to estimate the environmental footprint of SUD-L and R-L.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!