This review considers the pharmacology and indications for use of human albumin and synthetic colloids in general and transplantation surgery. The selection of a particular agent should be based on sound knowledge of their pharmacokinetic and pharmadynamic properties together with some consideration of cost. For correction of hypovolemia, human serum albumin solutions can adequately be replaced by present day colloids such as hydroxyethyl starch solutions. The duration of their effect in the intravascular space and their properties for plasma volume substitution or expansion are the main factors that will influence their selection. Albumin solutions, however, remain useful for treatment of all acute situations of hypovolemia accompanied by hypoalbuminemia during and after surgery.

Download full-text PDF

Source

Publication Analysis

Top Keywords

human albumin
8
albumin solutions
8
albumin colloid
4
colloid fluid
4
fluid replacement
4
replacement general
4
general surgery
4
surgery review
4
review considers
4
considers pharmacology
4

Similar Publications

A comprehensive strategy, including spectroscopic, molecular simulation, proteomics, and bioinformatics techniques, was employed to investigate a novel triazole, 5-(4-methoxyphenyl)-1-phenyl-1H-1,2,3-triazole, its interactions with high-abundance blood proteins, and identification of low-abundance proteins. The binding constants and thermodynamic parameters of the triazole to two high-abundance blood globular proteins, human serum albumin, and human immunoglobulin G (HIgG), were obtained by spectroscopic techniques and computational chemistry. The two-dimensional gel electrophoresis in combination with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was employed to isolate and identify differentially expressed low-abundance proteins in human blood serum samples following exposure to the triazole.

View Article and Find Full Text PDF

Background This study aimed to identify factors affecting the length of hospital stay (LOS) after total knee arthroplasty (TKA) in patients classified as American Society of Anesthesiologists (ASA) physical status I or II, with a focus on patient-dependent determination of discharge. The goal was to explore strategies to shorten LOS. Methods A retrospective cohort study was conducted on 398 patients (494 knees) who underwent primary TKA.

View Article and Find Full Text PDF

Introduction: Colorectal cancer (CRC) is one of the most common cancers occurring globally. Surgery for CRC often extends hospital stays due to complications, as patients must meet nutritional needs and regain mobility before discharge. Longer hospital stays, required for extended monitoring and care, can increase the risk of further complications, creating a cycle where extended stays lead to more issues.

View Article and Find Full Text PDF

BSA/PEI/GOD modified cellulose nanocrystals for construction of hydrogel-based flexible glucose sensors for sweat detection.

J Mater Chem B

January 2025

School of Chemistry and Materials Science, Ludong University, Key Laboratory of High Performance and Functional Polymer in the Universities of Shandong Province, Collaborative Innovation Center of Shandong Province for High Performance Fibers and Their Composites, Yantai 264025, China.

With the miniaturization, integration and intelligence of sweat electrochemical sensor technology, hydrogel flexible sensors have demonstrated immense potential in the field of real-time and non-invasive personal health monitoring. However, it remains a challenge to integrate excellent mechanical properties, self-healing properties, and electrochemical sensing capabilities into the preparation of hydrogel-based flexible sensors. The utilization of CBPG (cellulose nanocrystals (CNCs)@bovine serum albumin (BSA)@polyethyleneimine (PEI) glucose oxidase (GOD) nanomaterial) as both an enhancing phase and sensor probe within a hydrogel matrix, with poly(vinyl alcohol) (PVA) serving as the primary network constituent, has been proposed as a non-invasive technique for monitoring trace glucose levels in sweat.

View Article and Find Full Text PDF

Previous studies have shown that serum albumin levels are associated with a greater risk of metabolic syndrome (MetS). However, it is unclear whether this association is causal or only influenced by confounding factors, so further investigation is needed to determine the causal relationships. Researchers selected participants with serum albumin, metabolic syndrome, and related covariates from the National Health and Nutrition Examination Survey (NHANES) database for a total of 14,036 individuals, including 5483 individuals with MetS and 8553 individuals without MetS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!