Evaluation of Staph ID 32 system and Staph-Zym system for identification of coagulase-negative staphylococci.

J Clin Microbiol

Department of Clinical Microbiology, Bispebjerg Hospital, University of Copenhagen, Denmark.

Published: May 1995

The purpose of the investigation was to evaluate two commercially available identification systems: a new modification of the Staph-Zym system (Rosco, Tåstrup, Denmark) and the Staph ID 32 API system (API System, BioMérieux, Paris, France). A local standard method to be used in routine laboratories was also evaluated. A total of 200 staphylococcal isolates, including strains from both the American Type Culture Collection and the Czechoslovak Collection of Microorganisms as well as 89 clinical isolates, were used in tests of all three identification systems. The Staph ID 32 API system identified from 50 to 100% of the reference strains and 82.1% of the clinical isolates correctly. The Staph-Zym system identified from 90 to 100% of the reference strains and 82.1% of the clinical isolates correctly. Most misidentifications were of minor importance, but in both systems major failures appeared (Staphylococcus aureus was identified as a coagulase-negative staphylococcus). Both systems needed backup from a reference laboratory to determine if two isolates were of the same strain.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC228121PMC
http://dx.doi.org/10.1128/jcm.33.5.1150-1153.1995DOI Listing

Publication Analysis

Top Keywords

staph-zym system
12
api system
12
clinical isolates
12
identification systems
8
staph api
8
system identified
8
identified 100%
8
100% reference
8
reference strains
8
strains 821%
8

Similar Publications

In order to evaluate the usefulness of some phenotypic and genotypic methods for species identification of coagulase-negative staphylococci (CNS), isolates were obtained from bovine cases of clinical and sub-clinical mastitis from different geographical areas in Sweden. By using the Staph-Zym test, antimicrobial susceptibility testing, and sequencing of part of the CNS tuf gene and, when needed, part of the 16S rRNA gene we characterized 82 clinical isolates and 24 reference strains of 18 different species of staphylococci. The genotypic methods identified nine different species of CNS among the 82 milk isolates.

View Article and Find Full Text PDF

Five-test simple scheme for species-level identification of clinically significant coagulase-negative staphylococci.

J Clin Microbiol

March 2003

Departamento de Microbiología, Instituto de Investigaciones Médicas Alfredo Lanari, Facultad de Medicina, Universidad de Buenos Aires, Buenos Aires, Argentina.

A working scheme developed in our laboratory for identification (by species group and species) of coagulase-negative staphylococci (CNS) was evaluated with 201 consecutive isolates and then validated by using the reference method of Kloos and Schleifer (W. E. Kloos and K.

View Article and Find Full Text PDF

Coagulase-negative staphylococci (CNS), mainly isolated from bovine mastitis (n = 89, representing 11 different species), were used to evaluate two commercial identification systems: ID 32 Staph and Staph-Zym. The level of agreement between the ID 32 Staph and Staph-Zym systems and conventional methods was 77 and 94%, respectively. An alternative method, based on solid biochemical substrates, is also presented.

View Article and Find Full Text PDF

The aim of the study was the assessment of the usefulness of commercially available systems for rapid identification of staphylococci. API STAPH (bioMerieux, France), ID 32 STAPH (bioMerieux, France), GPL (HTL, Poland) and Staph-Zym (Rosco, Denmark). The identifications were carried out according to producer's instruction.

View Article and Find Full Text PDF

The Staph-Zym and the Rosco Set methods were used to assign species to 142 strains of staphylococci isolated from the milk of sheep with subclinical intramammary infection or teat skin, mouth of lambs or milking machine teat cups. One hundred eleven of the same strains were also tested by Standard Laboratory Culture Media. The Rosco Set assigned species to all strains tested, but the other two methods were unable to assign species to a similar proportion of isolates.