Distortion product otoacoustic emissions in healthy newborns: normative data.

Acta Otolaryngol

Department of Otorhinolaringology, Valencia University Clinic Hospital, University of Valencia, Spain.

Published: March 1995

Distortion product otoacoustic emissions (DPOAE) offer an alternative to transiently evoked otoacoustic emissions (TEOAE) as an audiological test. The former can be used as a screening technique, and may also provide frequency-specific information about the functional state of the cochlea. We recorded DPOAE in a group of healthy newborns to establish the characteristics of a DPOAE "audiogram" (DP-gram) in this population. The DP-gram can be obtained with characteristics quite similar to those observed in adults, with two sharp peaks of maximum amplitude at F2 frequencies of 2 kHz and 5-6 kHz, and a decline in DPOAE amplitude in midfrequencies. The results confirm the limitations of DPOAE recording for testing parts of the basilar membrane where lower frequencies are coded.

Download full-text PDF

Source
http://dx.doi.org/10.3109/00016489509139288DOI Listing

Publication Analysis

Top Keywords

otoacoustic emissions
12
distortion product
8
product otoacoustic
8
healthy newborns
8
dpoae
5
emissions healthy
4
newborns normative
4
normative data
4
data distortion
4
emissions dpoae
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?