Monoclonal antibodies against camel (Camelus dromedarius) IgG, IgM and light chains.

Vet Immunol Immunopathol

Department of Veterinary Pathology, University of Liverpool, UK.

Published: March 1995

Monoclonal antibodies specific for camel IgG and IgM heavy chains and immunoglobulin light chains were produced by a simple, time-saving and efficient method. Popliteal lymph nodes isolated 9 days after a primary foot-pad immunisation were used as the source of antibody producing hybridoma cells. Ascites was induced in mice and ascitic fluid collected. The specificity of anti-IgG and anti-IgM monoclonal antibodies was determined by enzyme-linked immunosorbent assay (ELISA) and Western blotting. Monoclonal antibodies specifically reacting to IgG1 subclasses were demonstrated; no monoclonal antibodies specific to IgG2 or IgG3 were generated. An unexpected finding was that some class-specific monoclonal antibodies were light chain, and not heavy chain, reactive.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0165-2427(94)05334-oDOI Listing

Publication Analysis

Top Keywords

monoclonal antibodies
24
igg igm
8
light chains
8
antibodies specific
8
monoclonal
6
antibodies
5
antibodies camel
4
camel camelus
4
camelus dromedarius
4
dromedarius igg
4

Similar Publications

Background: Population-adjusted indirect comparison using parametric Simulated Treatment Comparison (STC) has had limited application to survival outcomes in unanchored settings. Matching-Adjusted Indirect Comparison (MAIC) is commonly used but does not account for violation of proportional hazards or enable extrapolations of survival. We developed and applied a novel methodology for STC in unanchored settings.

View Article and Find Full Text PDF

Introduction: When a first anti-CGRP monoclonal antibody (anti-CGRP mAb) fails, switching to a different anti-CGRP mAb is an option often considered, despite this approach is not yet systemically studied.

Methods: We present the findings of a systematic review conducted according to the PRISMA recommendations on published studies - of any design - investigating the clinical outcomes after switching for any reason to different anti-CGRP mAbs.

Results: The literature search retrieved 76 records, while 19 papers were eventually reviewed.

View Article and Find Full Text PDF

Multiplexing Label-Free Polymeric Nanocarriers via Antipolymer Antibodies.

ACS Sens

January 2025

Centre for Advanced Imaging (CAI) and Australian Institute for Bioengineering and Nanotechnology, ARC Training Centre for Innovation in Biomedical Imaging Technology, The University of Queensland, St. Lucia, Queensland 4072, Australia.

Recent examples of immune responses directed against the synthetic polymer poly(ethylene glycol) (PEG) have led to the development of biocompatible polymers, which are viewed as promising candidates to act as surrogate materials for use in biological applications, such as hydrophilic poly(2-oxazoline)s (POx). Despite this, the characterization of critical aspects of the immune response against these emerging materials is sparse, in part because no known monoclonal antibodies (mAbs) against this family of synthetic material have been reported. To advance the understanding of such responses, we report the successful isolation and characterization of hybridoma-derived mAbs with excellent specificity for different POx species and notable selectivity for highly branched polymer architectures over linear systems.

View Article and Find Full Text PDF

A cytokine storm is marked by excessive pro-inflammatory cytokine release, and has emerged as a key factor in severe COVID-19 cases - making it a critical therapeutic target. However, its pathophysiology was poorly understood, which hindered effective treatment. SARS-CoV-2 initially disrupts angiotensin signalling, promoting inflammation through ACE-2 downregulation.

View Article and Find Full Text PDF

This study introduces the development of a highly sensitive label-free electrochemical immunosensor specifically designed to detect prostate-specific antigen (PSA). A glassy carbon electrode (GCE) coated with Au nanoparticles/polyhedral hollow CoCu bimetallic sulfide (CuCoS) was employed as a sensing interface for the fixation of the monoclonal anti-PSA antibody. The nanoarchitectures enhanced the capacity for loading prostate-specific antibodies (Ab) and effectually boosted electrical conductivity leading to enhance the electrochemical signal and greater sensitivity for the detection of PSA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!