Magnetic resonance imaging of optic nerves was obtained in 13 patients with acute optic neuritis and in 13 patients with a previous history of optic neuritis (ON), assessed by clinical, visual fields and visual evoked potentials evaluations. Results of the conventional short tau inversion recovery (STIR) sequence obtained with short time echo (STE-STIR: 22 ms) were compared with long time echo (LTE-STIR: 80 ms) sequence. The conventional STE-STIR sequence revealed lesions in 78.5% of acute ON and in 58.8% of optic nerves affected by previous ON. The LTE-STIR sequence was diagnostic in 92.8% of acutely symptomatic nerves, in 94.1% of nerves with previous ON. The calculated length of optic nerve lesions was significantly longer in imaging obtained with the LTE-STIR sequence than with the conventional STE-STIR sequences, both in acute and previous ON.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0720-048x(94)00600-h | DOI Listing |
Phys Med
January 2025
Center for Radiology, University Clinical Center of Vojvodina, Hajduk Veljkova 1-9, 21000 Novi Sad, Serbia; Faculty of Sciences, University of Novi Sad, Trg Dositeja Obradovića 3, 21000 Novi Sad, Serbia. Electronic address:
Objectives: To investigate the impact of compressed sensing - sensitivity encoding (CS-SENSE) acceleration factor on the diagnostic performance of magnetic resonance imaging (MRI) within standard female pelvis protocol in patients with endometrial cancer.
Methods: T2-weighted turbo spin echo (TSE) sequence from standard female pelvic MRI protocol was chosen due to its long acquisition time and essential role in the evaluation of morphological characteristics of the female pelvic anatomical structures. Fully sampled reference scans and multiple prospectively 2x to 5x under-sampled CS-SENSE scans were acquired.
Invest Radiol
January 2025
From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).
Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.
View Article and Find Full Text PDFA 65-year-old patient was admitted to the Institute with complaints of shortness of breath, palpitation, and limb edema. Comorbidities were type 2 diabetes mellitus, gout, obesity. Echo: left ventricular ejection fraction 22%, left ventricular aneurysm (LVA), floating thrombus 5.
View Article and Find Full Text PDFNonlinear Dyn
September 2024
Department of Mathematics, University College London, London, UK.
Time series is a data structure prevalent in a wide range of fields such as healthcare, finance and meteorology. It goes without saying that analyzing time series data holds the key to gaining insight into our day-to-day observations. Among the vast spectrum of time series analysis, time series classification offers the unique opportunity to classify the sequences into their respective categories for the sake of automated detection.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Department of Biomedical Engineering, University of Cincinnati, UC Bioscience Center, 3159 Eden Ave., Cincinnati, Ohio, 45221, UNITED STATES.
Ultrasound echo decorrelation imaging can successfully monitor and control thermal ablation of animal liver and tumor tissue ex vivo and in vivo. However, normal and diseased human liver has substantially different physical properties that affect echo decorrelation. Here, effects of human liver tissue condition on ablation guidance by three-dimensional echo decorrelation imaging are elucidated in experiments testing closed-loop control of radiofrequency ablation (RFA) in normal and diseased human liver tissue ex vivo.