A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemoglobin-based oxygen carrier preserves submaximal exercise capacity in humans. | LitMetric

Objective: The objective of this study was to evaluate the exercise capacity of subjects given an autologous transfusion or a polymerized bovine hemoglobin solution to define the pharmacodynamics and pharmacokinetics of a new hemoglobin-based oxygen carrier (HBOC-201).

Methods: Six normal healthy male subjects (ages 25 to 45 years) participated in this randomized, single-blind, two-way crossover study, which took place at Upjohn Research Clinics in Kalamazoo, Mich. A radial artery catheter was inserted in each subject before serial cardiac output and pulmonary function tests and phlebotomy of 15% blood volume (750 ml plus another 250 ml for study laboratories yields 1000 ml, or about 150 gm human hemoglobin). This was followed by isovolemic hemodilution with Ringer's lactate plus an autologous blood transfusion (or HBOC-201) and 1 week later 45 gm bovine hemoglobin of HBOC-201 (or autologous transfusion). Bicycle exercise stress tests to anaerobic threshold (approximately 65% of predicted maximum aerobic capacity) were done before phlebotomy and at approximately 45 minutes after the autologous transfusion or HBOC-201 infusion.

Results: Subjects had similar exercise and diffusion capacity but lower lactate levels (for up to 24 hours) during HBOC-201 (which paralleled plasma HBOC-201 levels) than during autologous transfusion periods. Oxygen use (uptake) and carbon dioxide production at rest were greater during the HBOC-201 infusion than during the autologous transfusion period. The half-life of HBOC-201 was about 23 hours.

Conclusions: Exercise capacity and diffusion capacity were similar after HBOC-201 and autologous transfusion. HBOC-201 resulted in greater oxygen (or uptake) and carbon dioxide production and lower lactate levels compared with autologous transfusion. Under the conditions of the study, the physiologic effects of 1 gm bovine hemoglobin of HBOC-201 were similar to 3 gm human hemoglobin from autologous transfusion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0009-9236(95)90057-8DOI Listing

Publication Analysis

Top Keywords

autologous transfusion
32
exercise capacity
12
bovine hemoglobin
12
transfusion hboc-201
12
hboc-201
10
autologous
9
transfusion
9
hemoglobin-based oxygen
8
oxygen carrier
8
human hemoglobin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!