Influence of the suprastructure on the peri-implant tissues in beagle dogs.

Clin Oral Implants Res

Department of Stomatology, Health Science Center, Dental Branch, University of Texas-Houston, USA.

Published: September 1995

The purpose of this study was to compare clinical, radiographic and histological differences around titanium oral implants loaded with either acrylic-veneered metal or ceramo-metal fixed prostheses. Five beagle dogs were used in this investigation. At the beginning of the study, all mandibular premolars and first molars were extracted. After 3 months of healing, 2 Brånemark implants were installed on each side of the mandibles. Three months later, abutments were inserted on each implant and a daily oral hygiene regime was initiated. One month after abutment connection, the implants on one side of the mandible were restored with an acrylic-veneered metal fixed prosthesis, whereas, on the other side a ceramo-metal fixed prosthesis was inserted. The prostheses were constructed in occlusion with the maxillary first molars. The following clinical parameters were measured around each implant at this time (i.e., baseline), and thereafter, at monthly intervals up to 5 months: Plaque Index; Gingival Index; implant mobility (using the Periotest); probing depth and clinical attachment level (using the Florida Probe). In addition, standardized radiographs were taken at baseline and 5 months after insertion of the prostheses and evaluated by subtraction radiography. Another Brånemark fixture was installed on each side of the mandibles 3 months before the end of the study. These implants remained unloaded and submerged for the entire study period. Five months after prosthesis insertion, the animals were killed, and implants with their supporting peri-implant tissues were processed for histological evaluation. Analyses of the clinical, radiographic and histometric parameters revealed no significant differences between the acrylic-veneered and ceramometal loaded implants.(ABSTRACT TRUNCATED AT 250 WORDS)

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0501.1995.060302.xDOI Listing

Publication Analysis

Top Keywords

peri-implant tissues
8
beagle dogs
8
clinical radiographic
8
acrylic-veneered metal
8
ceramo-metal fixed
8
installed side
8
side mandibles
8
fixed prosthesis
8
months
6
implants
5

Similar Publications

Effects of thread design on soft and hard tissue healing around implants in lipopolysaccharide-induced peri-implantitis-like lesions in rat maxillae.

J Oral Biosci

January 2025

Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8588, Japan. Electronic address:

Objectives: This study investigated the effects of thread design on the soft and hard tissues around implants in rat maxillary peri-implantitis-like lesions.

Methods: Fourteen, 9-week-old, female Wistar rats were used in this study. Two types of grade IV titanium tissue-level implants with a standard V-shape and buttress threads were prepared (control and test implants, respectively).

View Article and Find Full Text PDF

Periodontal Endoscopy for Mechanical Debridement in the Non-Surgical Management of Peri-Implantitis: A Narrative Review.

J Clin Med

January 2025

Department of Periodontology and Oral Mucosa Diseases, Medical University of Warsaw, Binieckiego 6 St., 02-097 Warsaw, Poland.

: The aim of the present narrative review is to synthesize the available scientific evidence on the effects of submarginal instrumentation with periodontal endoscopy and evaluate its' potential efficacy in terms of the non-surgical therapy of peri-implantitis. : The literature search was performed via electronic databases, including PubMed, Web of Science, Cochrane, and Scopus, and was supplemented by manual searching. A literature review was conducted addressing the following PICOS questions: (1) What is the efficacy of non-surgical submarginal instrumentation of the implant surface with the aid of a periodontal endoscope in patients with peri-implantitis? (2) What is the efficacy of non-surgical subgingival instrumentation performed with the aid of a periodontal endoscope compared with conventional subgingival instrumentation in patients with periodontitis, in terms of clinical parameters and patient-reported outcomes? Mechanical decontamination of the implant surface is crucial for resolving inflammation and arresting further bone loss.

View Article and Find Full Text PDF

Objective: To compare the influence of different emergence profile of implants in mandibular molar on the peri-implant soft tissue.

Methods: Forty-four implants were divided into two equal groups by mucosal thickness, ≥2 mm (group A) or < 2 mm (group B), and were randomly included in the test group and the control group. In the control group, the patients were treated by a prosthesis with no transmucosal modifications (subgroups A1 and B1).

View Article and Find Full Text PDF

Evaluation of keratinized tissue augmentation using amnion/chorion allograft vs. autogenous connective tissue in implant therapy: a retrospective study.

Clin Oral Investig

January 2025

Department of Surgical Sciences and Integrated Diagnostics, Unit of Implant and Prosthetic Dentistry, University of Genoa, Largo R. Benzi 10 , 16121 , Genova, Italy.

Objectives: Successful implant therapy must also ensure the integration of the soft tissues around the crown/abutment emergence profile. The existing literature does not consistently agree on the necessity of a minimal amount of keratinized tissue (KT), though it appears advantageous for the long-term stability and aesthetics of implants. The purpose of this clinical retrospective study is to compare the effectiveness of amnion/chorion membrane and autogenous subepithelial connective tissue in increasing the keratinized mucosa and maintaining it over a 5-year follow-up.

View Article and Find Full Text PDF

The surface topography and chemistry of titanium-aluminum-vanadium (Ti6Al4V) implants play critical roles in the osteoblast differentiation of human bone marrow stromal cells (MSCs) and the creation of an osteogenic microenvironment. To assess the effects of a microscale/nanoscale (MN) topography, this study compared the effects of MN-modified, anodized, and smooth Ti6Al4V surfaces on MSC response, and for the first time, directly contrasted MN-induced osteoblast differentiation with culture on tissue culture polystyrene (TCPS) in osteogenic medium (OM). Surface characterization revealed distinct differences in microroughness, composition, and topography among the Ti6Al4V substrates.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?