Median nerve somatosensory evoked responses (MnSSER) were recorded in 15 healthy adult patients, ASA I-II, before and during orthopaedic surgery. After induction of anaesthesia with fentanyl 0.1-0.15 mg, etomidate 0.3 mg kg-1 and vecuronium 0.1 mg kg-1, anaesthesia was maintained with 0.6% isoflurane (end-tidal) and 66% nitrous oxide in oxygen. MnSSER were recorded after establishment of steady-state anaesthesia at baseline, during preparation (n = 11) and continuously after the start of surgery. For the last measurement period, four patients were excluded from analysis because additional fentanyl was required. MnSSER were recorded at Erb's point, at C6 (neck) and at the respective contralateral primary somatosensory projection area (C3' or C4'). All MnSSER waveform components remained recordable and easily identifiable during anaesthesia. During intense surgical stimulation (e.g. periosteal stimulation) the peak-to-peak amplitude N20P25 increased significantly by more than 45% (P < 0.05), whereas latencies of all components did not change over time. These data indicate that MnSSER may be reliably monitored in the intraoperative period during steady-state isoflurane-nitrous oxide anaesthesia. In addition, concurrent changes in haemodynamic variables during nociceptive stimulation support the hypothesis that reversal of isoflurane-nitrous oxide-induced suppression of MnSSER may indicate increased nociceptive input when depth of anaesthesia is inadequate.

Download full-text PDF

Source
http://dx.doi.org/10.1093/bja/75.5.598DOI Listing

Publication Analysis

Top Keywords

mnsser recorded
12
surgical stimulation
8
median nerve
8
nerve somatosensory
8
somatosensory evoked
8
evoked responses
8
isoflurane-nitrous oxide
8
oxide anaesthesia
8
anaesthesia
7
mnsser
6

Similar Publications

Purpose: Median nerve somatosensory evoked responses (MnSSER) alterations were compared to clinical tests (cold and pinprick) variations, in 20 ASA I adult patients following infraclavicular block obtained with 40 mL ropivacaine 0.5% to assess first, the difference of time course of the respective electrophysiological and clinical signs, and second, the objectivity and the reproducibility of MnSSER changes.

Clinical Features: Four MnSSER derivations (Erb's point; cutaneous projection of peripheral end of brachial plexus; posterior neck at C6 level, frontal and controlateral parietal scalp) were monitored and recorded for retrospective analysis.

View Article and Find Full Text PDF

Background: Mid-latency somatosensory evoked responses are used to monitor the integrity of the sensory pathways intra-operatively. They can quantify the effects of anaesthetics on the central nervous system. Mid-latency auditory evoked responses have been related to cognition during anaesthesia, but there are no detailed studies using median nerve somatosensory evoked responses (MnSSER).

View Article and Find Full Text PDF

Median nerve evoked responses: stimulation modalities for midlatency cortical components.

Electromyogr Clin Neurophysiol

December 2001

Department of Anaesthesiology, University Hospital Charité, Berlin, Germany.

Purpose: Median nerve somatosensory evoked responses (MnSSER) are frequently used clinically and scientifically. However, the stimulus-response interrelationship has not been documented for the midlatency components. Therefore we investigated the spinal and cortical midlatency MnSSER, to document the effect of different stimulus intensities.

View Article and Find Full Text PDF

Cortical arousal in critically ill patients: an evoked response study.

Intensive Care Med

September 2000

Department of Anaesthesiology and Intensive Care, University Hospital Charité, Berlin, Germany.

Objective: Assessing the level of sedation in critically ill patients remains a challenge for the intensivist in order to avoid over or under-sedation. Clinical scoring systems may fail in patients with concomitant neurological disorders or requiring muscle relaxants. We evaluated auditory (AER) and median nerve somatosensory evoked responses (MnSSER) in critically ill patients sedated with sufentanil and propofol, in order to quantify the level of sedation during therapeutic interventions.

View Article and Find Full Text PDF

Background: Median nerve somatosensory evoked responses (MnSSER) are frequently used to monitor the integrity of the somatosensory pathway during surgery. We investigated MnSSER components during the wakeup phase from anaesthesia with propofol/sufentanil, because detailed information is lacking about the reversibility of anaesthetic induced changes of MnSSER. The aim of the study was to document precisely the MnSSER waves in relation to the clinical awakening.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!