Background: Measurement of the carbon monoxide transfer factor (TLCO) has traditionally been performed using the single breath method but recently the intrabreath method has been developed. The aim of this study was to compare the two methods in the clinical evaluation of patients with obstructive and non-obstructive pulmonary disorders.

Methods: Measurements of TLCO with the intrabreath method were carried out on a study sample composed of 50 patients with non-obstructive disorders and 50 with airways obstruction (FEV1/FVC < 70%) either before or after a single breath measurement of the TLCO had been performed. The method involves the continuous analysis of a single slow expirate using a computerised rapid multigas infrared analyser. TLCO, alveolar volume (VA), TLCO/VA, and inspired vital capacity (IVC) values were obtained for both groups by both methods.

Results: When measured with the intrabreath method the group with airways obstruction showed lower TLCO and TLCO/VA values than the non-obstructive group. VA was higher in both patient groups when measured with the intrabreath technique. The same test also showed higher TLCO values with the intrabreath method in the group with non-obstructive disorders and lower TLCO/VA values with the intrabreath method in those with airways obstruction. The corresponding parameters obtained by the two methods correlated closely, with no correlation between the magnitude of the differences with the magnitude of the readings. An index of gas mixing indicated a better distribution of the inspired air for the intrabreath method than for the single breath method. The VA values obtained with the intrabreath method showed a closer agreement to the actual total lung capacities measured by body plethysmography.

Conclusion: The intrabreath method of determining TLCO is comparable to the traditional single breath method. Measurement of alveolar volume by the intrabreath method approximates more closely to total lung capacity, even in subjects with airways obstruction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC474915PMC
http://dx.doi.org/10.1136/thx.50.8.902DOI Listing

Publication Analysis

Top Keywords

intrabreath method
40
single breath
20
airways obstruction
20
method
14
breath method
12
values intrabreath
12
intrabreath
11
method measurement
8
measurement carbon
8
carbon monoxide
8

Similar Publications

Background: Longitudinal measurements of intrabreath respiratory impedance (Zrs) in preschool-aged children may be able to distinguish abnormal lung function trajectories in children with a history of wheezing compared to healthy ones.

Methods: Children from a prospective, longitudinal community-based cohort performed annual intrabreath oscillometry (IB-OSC) measurements from age 3- to 7-years. IB-OSC was performed using a single 10 Hz sinusoid while clinically asymptomatic.

View Article and Find Full Text PDF

Background: Intra-breath oscillometry has been proposed as a sensitive means of detecting airway obstruction in young children. We aimed to assess the impact of early life wheezing and lower respiratory tract illness on lung function, using both standard and intra-breath oscillometry in 3 year old children.

Methods: History of doctor-diagnosed asthma, wheezing, bronchiolitis and bronchitis and hospitalisation for respiratory problems were assessed by questionnaires in 384 population-based children.

View Article and Find Full Text PDF

Background: Continuous positive airway pressure (CPAP) therapy has profound effects in obesity hypoventilation syndrome (OHS). Current therapy initiation focuses on upper airway patency rather than the assessment of altered respiratory mechanics due to increased extrapulmonary mechanical load.

Methods: We aimed to examine the viability of intra-breath oscillometry in optimizing CPAP therapy for OHS.

View Article and Find Full Text PDF

Respiratory resistance (Rrs) and reactance (Xrs) as measured by oscillometry and their intrabreath changes have emerged as sensitive parameters for detecting early pathological impairments during tidal breathing. This study evaluates the prevalence and association of abnormal oscillometry parameters with respiratory symptoms and respiratory diseases in a general adult population. A total of 7,560 subjects in the Austrian LEAD (Lung, hEart, sociAl, boDy) Study with oscillometry measurements (computed with the Resmon Pro FULL; Restech Srl) were included in this study.

View Article and Find Full Text PDF

Association of forced oscillation technique measurements with respiratory system compliance and resistance in a 2-compartment physical model.

Respir Med Res

November 2023

Centre d'étude des pathologies respiratoires / Inserm UMR1100, Université de Tours, Tours, France; Service de Pneumologie et Explorations Fonctionnelles Respiratoires, CHRU de Tours, Tours, France. Electronic address:

Background: The forced oscillation technique (FOT) may be useful for diagnosis and follow-up of respiratory diseases. It is unclear how global or regional alterations in airway resistance (Raw) and lung compliance (C) alter FOT measurements.

Methods: A 2-compartment physical model of the respiratory system allowed to simulate variations in Raw, C, and their heterogeneity during tidal breathing in an adult human.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!