Objectives: This prospective study assessed the initial hemodynamic effects and long-term clinical benefits of dual-chamber pacing with a short atrioventricular (AV) delay in patients with chronic heart failure who had no traditional indication for pacemaker implantation.

Background: Dual-chamber pacing with a short AV delay has been proposed as a nonpharmacologic treatment for drug-refractory heart failure. Both initial and long-term hemodynamic as well as functional benefits have been reported. All previous studies have used an AV delay of 100 ms. Despite encouraging results, these previous studies have been anecdotal and uncontrolled.

Methods: This double-blind, randomized, crossover trial included 12 subjects with chronic congestive heart failure despite optimal medical therapy. Patients were required to be in sinus rhythm with no evidence of significant bradyarrhythmias. On the day after implantation of a dual-chamber pacemaker, invasive hemodynamic measurements were made at varying AV delays between 100 and 200 ms. Patients were then randomized to either dual-chamber pacing with a 100-ms AV delay or backup mode (VVI at 40 beats/min). After 4 to 6 weeks, crossover to the other pacing mode was programmed.

Results: Hemodynamic measurements on the day after pacemaker implantation demonstrated no benefit of pacing with any AV delay compared with intrinsic conduction. At the optimal AV interval for each patient, neither cardiac output (4.5 +/- 1.5 vs 4.7 +/- 1.6 liters/min [mean +/- SD]) nor wedge pressure (16 +/- 10 vs 17 +/- 8 mm Hg) improved significantly from baseline measurements during intrinsic conduction. The long-term pacing protocol was completed in nine patients. Ejection fraction was 16 +/- 6% with dual-chamber (VDD mode) pacing and 18 +/- 4% in backup mode (p = NS). No patient had an increase in ejection fraction by > or = 5% with VDD pacing, nor did any patient improve in New York Heart Association functional class with short AV delay dual-chamber pacing. Also, there were no significant reductions in body weight or diuretic requirements during this pacing period.

Conclusions: Dual-chamber pacing with a short AV delay does not improve hemodynamic and clinical status or ejection fraction measured on the day after pacemaker implantation in patients with chronic congestive heart failure. Routine use of pacemaker therapy with a short AV delay aas a primary treatment of heart failure in patients without standard arrhythmic indications is unwarranted.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0735-1097(95)00292-0DOI Listing

Publication Analysis

Top Keywords

dual-chamber pacing
24
heart failure
24
pacing short
16
short delay
16
congestive heart
12
ejection fraction
12
pacing
11
delay
9
dual-chamber
8
short atrioventricular
8

Similar Publications

Leadless Pacing: Current Status and Ongoing Developments.

Micromachines (Basel)

January 2025

Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.

Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.

View Article and Find Full Text PDF

Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.

Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.

View Article and Find Full Text PDF

There is an increased risk of cardiac complications in COVID-19 among patients with pre-existing comorbidities due to their existing pro-inflammatory status. The manifestation of complete heart block has been evidenced as transient and in no need of intervention. This case presents a previously healthy woman who was diagnosed with SARS-CoV-2 infection and complete heart block; she underwent permanent dual-chamber pacemaker implantation after successful treatment and a negative COVID-19 test.

View Article and Find Full Text PDF

Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.

Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.

View Article and Find Full Text PDF

3D computed tomography integration guiding permanent Aveir AR leadless pacemaker implantation: a case report.

Eur Heart J Case Rep

January 2025

AL Qassimi Hospital, Emirates Health Services (EHS), Wasit Street-Al khazamiya, Sharjah 3500, United Arab Emirates.

Background: The use of single-chamber, right ventricular (RV) leadless pacemakers (LPs) has been well established, the introduction of a right atrial LPs has opened the door for dual-chamber leadless pacing. Cardiac computed tomography (CT) segmentation integration might provide proper visual guide during the procedure.

Case Summary: A 58-year-old male patient was brought to the emergency department with dizziness and complete heart block.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!