A new technique, the 3-dimensional technique, has been developed. Using a digitzer, points taken from anteroposterior and lateral radiographs are input into a personal computer. A 3-dimensional solid model of the prosthesis is created using custom software. Tilt and anteversion of the acetabular cup are measured, and the model is rotated to a standard frontal view, allowing measurement of femoral head displacement from the center of the acetabular cup. Comparing serial radiographs of the same patient gives the direction and distance of femoral head displacement over time, and this value is used to calculate the minimum volume of polyethylene debris generated. The 3-dimensional technique has been validated by construction of a precision acrylic phantom, and milling of a metal-backed acetabular cup to simulate polyethylene wear. Three-dimensional measurement of femoral head displacement using this technique has an accuracy of +/- 0.15 mm, and volume calculations are within 8% of the true amount of polyethylene removed from the cup. The 3-dimensional technique gives previously unavailable information, and can be used for clinical evaluation of polyethylene wear and evaluation of new prosthetic designs and bearing surfaces.
Download full-text PDF |
Source |
---|
Environ Res
January 2025
Southern California Coastal Water Research Project, Costa Mesa, CA, 92626.
The concentration, character, and distribution of microplastics in coastal marine environments remain poorly understood, with most research focusing on the abundance of microplastics at the sea surface. To address this gap, we conducted one of the first comprehensive assessments of microplastic distribution through the marine water column and in the benthic sediment during the wet and dry season in the coastal waters of the San Pedro Shelf, Southern California, USA. Microplastic concentrations in the water column did not vary significantly across season but were significantly higher in nearshore environments and at the surface of the water column.
View Article and Find Full Text PDFArthroplast Today
December 2024
Hospital Pavia Arecibo, Arecibo Orthopedic Institute, Arecibo, PR, USA.
Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.
View Article and Find Full Text PDFSurg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFCureus
December 2024
Medical Affairs, Dr. Reddy's Laboratories Ltd., Hyderabad, IND.
Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopaedic Surgery, Fiona Stanley Fremantle Hospitals Group, Murdoch, Western Australia, Australia.
Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!