In the present study, we examined the hypothesis that dynamic characteristics of flow modulate the production of vasoactive mediators, namely nitric oxide (NO) and endothelin-1 (ET-1), by human umbilical vein endothelial cells (HUVECs). Cells were exposed for 6 hours in a cone-and-plate apparatus to different types of flow: steady laminar, with shear stresses of 2, 8, and 12 dyne/cm2, pulsatile laminar, with shear stress from 8.2 to 16.6 dyne/cm2 and a frequency of 2 Hz; periodic laminar, with square wave cycles of 15 minutes and shear stress from 2 to 8 dyne/cm2, and turbulent, with shear stress of 8 dyne/cm2 on average. A second culture dish was kept in a normal incubator as a static control for each experiment. Laminar flow induced synthesis of NO by HUVECs that was dependent on shear-stress magnitude. Laminar shear stress at 8 dyne/cm2 also upregulated the level of NO synthase mRNA. As observed with steady laminar flow, pulsatile flow also induced an increase in NO release by endothelial cells. When HUVECs were subjected to step-change increases of laminar shear, a further increase of NO synthesis was observed, compared with steady laminar shear of the same magnitude. Turbulent flow did not upregulate NO synthase mRNA or increase NO release. Both laminar and turbulent shear stress reduced, although not significantly, ET-1 mRNA and ET-1 production compared with the static condition. These results indicate that local blood flow conditions modulate the production of vasoactive substances by endothelial cells. This may affect vascular cell functions such as nonthrombogenicity, regulation of blood flow, and vascular tone.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.res.76.4.536DOI Listing

Publication Analysis

Top Keywords

laminar shear
20
shear stress
20
endothelial cells
16
steady laminar
12
stress dyne/cm2
12
flow
9
laminar
9
nitric oxide
8
flow conditions
8
modulate production
8

Similar Publications

The role of fluid friction in streamer formation and biofilm growth.

NPJ Biofilms Microbiomes

January 2025

FLOW, Department of Engineering Mechanics, KTH, Stockholm, Sweden.

Biofilms constitute one of the most common forms of living matter, playing an increasingly important role in technology, health, and ecology. While it is well established that biofilm growth and morphology are highly dependent on the external flow environment, the precise role of fluid friction has remained elusive. We grew Bacillus subtilis biofilms on flat surfaces of a channel in a laminar flow at wall shear stresses spanning one order of magnitude (τ = 0.

View Article and Find Full Text PDF

Microfluidic chips are powerful tools for investigating numerous variables including chemical and physical parameters on protein aggregation. This study investigated the aggregation of bovine serum albumin (BSA) in two different systems: a vial-based static system and a microfluidic chip-based dynamic system in which BSA aggregation was induced successfully. BSA aggregation induced in a microfluidic chip on a timescale of seconds enabled a dynamic investigation of the forces driving the aggregation process.

View Article and Find Full Text PDF

High Shear Stress Reduces ERG Causing Endothelial-Mesenchymal Transition and Pulmonary Arterial Hypertension.

Arterioscler Thromb Vasc Biol

December 2024

Department of Pediatrics (T.S., J.-R.M., Y.H.C., J.M.S., J. Kaplan, A.C., L.W., D.G., S.T., S.I., M.D., W.Y., A.L.M., M.R.).

Background: Computational modeling indicated that pathological high shear stress (HSS; 100 dyn/cm) is generated in pulmonary arteries (PAs; 100-500 µm) in congenital heart defects causing PA hypertension (PAH) and in idiopathic PAH with occlusive vascular remodeling. Endothelial-to-mesenchymal transition (EndMT) is a feature of PAH. We hypothesize that HSS induces EndMT, contributing to the initiation and progression of PAH.

View Article and Find Full Text PDF

Analysis of Entropy Generation for Mass and Thermal Mixing Behaviors in Non-Newtonian Nano-Fluids of a Crossing Micromixer.

Micromachines (Basel)

November 2024

Department of Mechanical Engineering, Inha University, 100, Inha-ro, Michuhol-gu, Incheon 22212, Republic of Korea.

This work's objective is to investigate the laminar steady flow characteristics of non-Newtonian nano-fluids in a developed chaotic microdevice known as a two-layer crossing channels micromixer (TLCCM). The continuity equation, the 3D momentum equations, and the species transport equations have been solved numerically at low Reynolds numbers with the commercial CFD software Fluent. A procedure has been verified for non-Newtonian flow in studied geometry that is continuously heated.

View Article and Find Full Text PDF

Investigating magnetic blood flow characteristics through arteries and micron-size channels for clinical therapies in biomedicine is becoming increasingly important with the rise of point-of-care diagnostics devices. A computational fluid dynamics (CFD) investigation is conducted to explore blood flow within a coronary artery affected by an elliptical stenosis near the artery wall under the influence of a magnetic field. The novelty of our study is the integration of Navier-Stokes and Maxwell's equations to calculate body forces on fluid flow, coupled with the application of magnetic fields both longitudinally and vertically, and the use of the Carreau-Yasuda model to analyse non-Newtonian blood rheology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!