Avidin and 111In-labelled biotin scan: a new radioisotopic method for localising vascular graft infection.

Eur J Vasc Endovasc Surg

Institute for Cardiovascular and Respiratory Disease, Scientific Institute H. San Raffaele, University of Milano, Italy.

Published: November 1995

Objectives: To evaluate a new imaging technique, for diagnosis of prosthetic vascular graft infection. Avidin is a protein which accumulates nonspecifically at sites of inflammation or infection. Due to its extremely low dissociation constant with biotin sites of infection can be imaged, using avidin as a pre-target, followed by injection of 111In-labelled biotin. This technique is much simpler than the common scintigraphic methods which employ labelling of blood components and its target-to-background ratio is greater than the methods employing radiolabelled proteins.

Design: Prospective clinical study.

Setting: A single department of vascular surgery and one of nuclear medicine of a Northern Italian hospital.

Materials: Between May 1993 and May 1994, 31 grafts in 26 patients were studied; the series included 23 men and three women with a mean age of 65.5 years (range 54-76 years). The prosthetic graft (Dacron -16, ePTFE -15) were: aortoaortic 5, aortobifemoral 15, aortoiliac 1, and femoropopliteal 10. Sixteen patients were suspected of having a vascular graft infection (Group A), the other 10 patients served as controls (Group B). 20 mg of Avidin were injected iv, followed 24 h later by i.v. injection of 500 micrograms of Biotin labelled with 74 MBq of 111In.

Chief Outcome Measures: Whole-body imaging was performed at 10 min and 2 h post-injection, along with SPECT imaging when indicated. Scan results were correlated with the traditional imaging modalities and the clinical outcome of the patients.

Main Results: In Group A: two patients (three grafts) were excluded from the study, there were six true-positives, one false-positive and 11 true-negatives. Results in Group B: 10 true-negatives. The overall sensitivity was 100%, the specificity 95%, the accuracy 96%, the positive predictive value 86% and the negative predictive value 100%.

Conclusions: These data suggest that Avidin/111In-labelled Biotin scintigraphy is a useful non invasive diagnostic method for early diagnosis of suspected prosthetic vascular graft infection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1078-5884(05)80162-5DOI Listing

Publication Analysis

Top Keywords

vascular graft
16
graft infection
16
111in-labelled biotin
8
prosthetic vascular
8
group patients
8
infection
6
biotin
5
vascular
5
graft
5
avidin
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!