The limited contact dynamic compression plate and partial contact plate were designed to decrease contact with cortical bone in an attempt to decrease cortical ischemia, remodeling, and eventual porosis under the plate after use of standard dynamic compression plates. This study quantified cortical bone blood flow beneath the plate with these three different designs in a sheep tibia fracture model. In 18 skeletally immature sheep, the right tibia was fractured and then was internally fixed with an interfragmentary screw and a dynamic compression plate, limited contact dynamic compression plate, or partial contact plate. At 12 weeks, cortical bone perfusion was assessed with laser Doppler flowmetry in nine areas beneath the plate. The baseline (before fracture) cortical bone cell flux averaged 100 +/- 60 mV. After fracture, this decreased to 60 +/- 48 mV (p < 0.0003); immediately after plating, the perfusion averaged 29 +/- 25 mV (p < 0.01). Cortical bone perfusion then increased to 106 +/- 52, 165 +/- 71, and 163 +/- 71 mV at 2, 6, and 12 weeks after fracture (p < 0.001 for all when compared with values after plating). No significant differences in cortical perfusion were seen between the types of plate. Cortical porosity under the plate was assessed with digital density analysis of microradiographs of this region. No significant difference was seen between the types of plate in this analysis or in biomechanical and disulphine blue perfusion analysis. Thus, no significant advantage was seen for the new plate designs used in this model. This lack of advantage may be a result of the immature animals used in the study, the protocol for blood flow measurement, the invasive periosteal stripping employed to create the fracture, or all three. However, as advantages with the new plate designs have been seen in other studies, this area warrants further investigation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.1100130511 | DOI Listing |
Acta Bioeng Biomech
June 2024
3School of Mechanical Engineering, Yanshan University, Hebei, China.
: This study aimed to explore how the microarchitectural features of lacunae and perilacunar zones impact the biomechanics of microdamage accumulation in cortical bone, crucial for understanding bone disorders' pathogenesis and developing preventive measures. : Utilizing the phase field finite element method, the study analyzed three bone unit models with varying microarchitecture: one without lacunae, one with lacunae and one including perilacunar zones, to assess their effects on cortical bone's biomechanical properties. : The presence of lacunae was found to increase microcrack initiation risk, acting as nucleation points and accelerating microcrack propagation.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
The otic capsule and surrounding temporal bone exhibit complex 3D motion influenced by frequency and location of the bone conduction stimulus. The resultant correlation with the intracochlear pressure is not sufficiently understood, thus is the focus of this study, both experimentally and numerically. Experiments were conducted on six temporal bones from three cadaver heads, with BC hearing aid stimulation applied at the mastoid and classical BAHA locations across 0.
View Article and Find Full Text PDFJ Prosthodont
January 2025
Department of Clinical and Biological Sciences, University of Turin, Turin, Italy.
Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.
Materials And Methods: Two implant sites were prepared in the tibia of four minipigs.
J Dent Sci
January 2025
Department of Oral and Maxillofacial Radiology, Yonsei University College of Dentistry, Seoul, Republic of Korea.
Background/purpose: This study analyzed the clinical and imaging features of lingual mandibular bone depression (LMBD) in the anterior mandible, aiming to prevent misdiagnosis and unnecessary surgical procedures.
Materials And Methods: The patients who visited a university dental hospital for painless radiolucency in the anterior mandible from January 2010 to December 2022 were retrospectively reviewed. Twelve cases of LMBD in the anterior mandible that are confirmed by biopsy or long-term follow-up were identified.
J Dent Sci
January 2025
Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Background/purpose: The use of finite element (FE) analysis in implant biomechanics offers many advantages over other approaches in simulating the complexity of clinical situations. The aim of this study was to perform an optimization analysis of dental implants with different thread designs in three types of bone quality.
Materials And Methods: The three-dimensional FE model of a mandibular bone block with a screw-shaped dental implant and superstructure was simulated.