Liver aspiration biopsies performed with a new disposable instrument (Hepafix) were compared with biopsies performed with the conventional Menghini's needle in 74 patients. The diameter of the needle was the same in both groups, being either 1,4 or 1,6 mm depending upon the case. Twenty-seven of the 39 patients (69,2%) biopsied with the new instrument experienced no pain during puncture, as opposed to only 9 of the 35 patients (25,7%) biopsied with the standard needle. In non-cirrhotic patients, tissue fragments were longer with Hepafix (mean, 40 mm) than with Menghini's needle (mean, 25 mm). The authors' preference goes to Hepafix because it is less painful, responsibly cheap and carries no risk of viral contamination.

Download full-text PDF

Source

Publication Analysis

Top Keywords

disposable instrument
8
instrument hepafix
8
biopsies performed
8
menghini's needle
8
[liver aspiration
4
aspiration biopsy
4
biopsy disposable
4
hepafix
4
hepafix author's
4
author's transl]
4

Similar Publications

Evaluation of hazardous substances emitted during mask use.

Environ Int

January 2025

Department of Environmental Health Sciences, Graduate School of Public Health, Seoul National University, Seoul, Republic of Korea; Institute of Health and Environment, Seoul National University, Seoul, Republic of Korea. Electronic address:

This study evaluated the inhalation of mask-derived materials by simulating real breathing conditions and examined how the amount of inhaled materials varies with breathing flow rate and duration. Three types of non-certified reusable masks and two types of certified disposable masks were selected. For each mask, five different hazardous materials were captured and analyzed in three replicates with two breathing flow rates of 30 L/min and 85 L/min and two breathing time combinations of 15 min and 60 min.

View Article and Find Full Text PDF

A label-free, flexible, and disposable aptasensor was designed for the rapid on-site detection of vancomycin (VAN) levels. The electrochemical sensor was based on lab-printed carbon electrodes (C-PE) enriched with cauliflower-shaped gold nanostructures (AuNSs), on which VAN-specific aptamers were immobilized as biorecognition elements and short-chain thiols as blocking agents. The AuNSs, characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM), enhanced the electrochemical properties of the platform and the aptamer immobilization active sites.

View Article and Find Full Text PDF

In this work, laser-induced graphene from kraft paper (kraft paper-LIG) was employed for the nonenzymatic electrochemical sensing of dopamine (DA). We reported the fabrication and characterization of a disposable, cost-effective, kraft-based electrochemical dopamine sensor with the sensing electrode consisting of laser-induced graphene derived from kraft paper. Kraft paper-LIG was formed by the femtosecond laser modification of kraft paper into a three-dimensional (3D) graphene arrangement.

View Article and Find Full Text PDF

A thermoplastic chip for 2D and 3D correlative assays combining screening and high-resolution imaging of immune cell responses.

Cell Rep Methods

January 2025

Department of Applied Physics, Science for Life Laboratory, KTH Royal Institute of Technology, Stockholm, Sweden; Department of Medicine, Center for Infectious Medicine, Huddinge, Karolinska Institutet, Stockholm, Sweden. Electronic address:

We present an easy-to-use, disposable, thermoplastic microwell chip designed to support screening and high-resolution imaging of single-cell behavior in two- and three-dimensional (2D and 3D) cell cultures. We show that the chip has excellent optical properties and provide simple protocols for efficient long-term cell culture of suspension and adherent cells, the latter grown either as monolayers or as hundreds of single, uniformly sized spheroids. We then demonstrate the applicability of the system for single-cell analysis by correlating the dynamic cytotoxic response of single immune cells grown under different metabolic conditions to their intracellular cytolytic load at the end of the assay.

View Article and Find Full Text PDF

Ambiguity in robotic surgical instruction: lessons from remote and in-person simulation.

Adv Health Sci Educ Theory Pract

January 2025

Department of Surgery, University of California San Francisco, 513 Parnassus Avenue S-321, San Francisco, CA, 94143, USA.

The rise of robotic surgery has been accompanied by numerous educational challenges as surgeons and trainees learn skills unique to the robotic platform. Remote instruction is a solution to provide surgeons ongoing education when in-person teaching is not feasible. However, surgical instruction faces challenges from unclear communication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!