Complications after construction of a continent ileostomy may require reoperation to restore continence. Although most patients accept another operation, a few refuse further operative intervention. In such patients we have employed an indwelling ileostomy valve device. A Silastic tube with a circumferential balloon to provide a leakproof seal functionally replaces the nipple valve that has failed. In 14 patients, the valve device has maintained continuous and voluntary control over evacuation without untoward local or systemic effects. If further investigation continues to support this approach to maintaining continence, use of an indwelling ileostomy valve device might be preferable to continued creation of the nipple valve.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0002-9610(81)90022-2 | DOI Listing |
Cochrane Database Syst Rev
January 2025
Department of Pharmacy Practice, University of Connecticut, Storrs, CT 06269, USA.
Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.
Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.
Circ Cardiovasc Interv
January 2025
Department of Cardiac Surgery, University of Michigan, Ann Arbor (G.A.).
Background: The association, if any, between the transmitral mean pressure gradient (TMPG) after mitral transcatheter edge-to-edge repair and 1-year mortality is controversial in patients undergoing mitral transcatheter edge-to-edge repair with the MitraClip system. We sought to estimate the association between intraoperatively measured residual mitral regurgitation (rMR) and TMPG and 1-year mortality among patients undergoing mitral transcatheter edge-to-edge repair to facilitate decisions on additional devices.
Methods: In patients with severe secondary (functional) MR, we analyzed registry data using generalized estimating equations.
BMC Cardiovasc Disord
January 2025
Department of Medical Ultrasonics, the First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
Background: Transcatheter valve-in-valve replacement (TMViVR) is an alternative option for patients with bioprosthetic valve failure (BVF) who are at high surgical risk. Although infective endocarditis (IE) after transcatheter mitral valve-in-valve replacement is unusual, it is associated with significantly high mortality.
Case Presentation: An 81-year-old male patient was admitted with intermittent thoracic tightness, chest pain persisting for 3 years, and shortness of breath with nausea for 1 week.
Sci Rep
January 2025
Emergency Department, The State Key Laboratory for Complex, Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China.
Variation in the incidence, survival rate and factors associated with survival after cardiac arrest in China is reported. Some studies have tried to fill the knowledge gap regarding the epidemiology of cardiac arrest in China but were unable to identify reasons for the reported differences. Therefore, the purpose of this study was to describe Chinese management of cardiac arrest, particularly from the perspective of compression, ventilation, monitoring, treatment, and extracorporeal cardiopulmonary resuscitation.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Second Division of Cardiology, Cardiac-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy.
This case details the successful implantation of a leadless pacemaker following the extraction of transvenous leads in a 72-year-old female patient with a complex cardiovascular history. The patient had undergone a series of cardiac interventions, including a recent percutaneous tricuspid valve repair with a metal clip implant due to severe regurgitation. After presenting with an infection at the pacemaker site, methicillin-resistant Staphylococcus hominis was identified, necessitating the removal of the entire pacing system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!