Download full-text PDF

Source

Publication Analysis

Top Keywords

radiopharmaceutical quality
4
quality assurance--pilot
4
assurance--pilot study
4
radiopharmaceutical
1
assurance--pilot
1
study
1

Similar Publications

Colony-stimulating factor 1 receptor (CSF1R) is almost exclusively expressed on microglia in the human brain and thus, has promise as a biomarker for imaging microglia density as a proxy for neuroinflammation. [C]CPPC is a radiotracer with selective affinity to CSF1R, and has been evaluated for in-human microglia PET imaging. The flourine-18 labeled CPPC derivative, 5-cyano-N-(4-(4-(2-[F]fluoroethyl)piperazin-1-yl)-2-(piperidin-1-yl)phenyl)furan-2-carboxamide ([F]FCPPC), was previously synthesized, however, with a low radiochemical yield using manual radiosynthesis.

View Article and Find Full Text PDF

Association of -607C/A (rs1946518) and -137G/C (rs187238) polymorphisms and immune response in radiation-exposed workers.

Int J Radiat Biol

January 2025

Research Center for Radioisotope, Radiopharmaceutical, and Biodosimetry Technology, Research Organization for Nuclear Energy, National Research and Innovation Agency, Serpong, Indonesia.

Purpose: Interleukin-18, transforming growth factor-β, and superoxide dismutase are important cytokines and antioxidants in protecting the body from damage caused by radiation exposure through an immune response mechanism. Genetic polymorphisms -607 C/A and -137 G/C are thought to affect the IL-18 cytokine in carrying out its function as a biomarker to indicate adverse conditions due to radiation. The purposes of this study were to investigate the association between 607 C/A and -137 G/C SNPs on the concentrations of IL-18, and to measure TGF-β and SOD activity in radiation workers and control group.

View Article and Find Full Text PDF

Design, Synthesis, and Imaging of a Stable Xanthene-Based Dye with NIR-II Emission up to 1450 nm.

Anal Chem

January 2025

Center for Advanced Materials Research & Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, P. R. China.

The development of long-wavelength near-infrared II (NIR-II, 900-1700 nm) dyes is highly desirable but challenging. To achieve both red-shifted absorption/emission and superior imaging capabilities, a donor-acceptor-donor (D-A-D) xanthene core was strategically modified by extending π-conjugated double bonds and enhancing electron-donating properties. Two dyes named and were synthesized and exhibited notably red-shifted absorption/emission peaks at 942/1250 and 1098/1450 nm, respectively.

View Article and Find Full Text PDF

Validation of an alternative two-strip method for the quality control of [Tc]Tc-ETIFENIN (TECHIDA®).

Appl Radiat Isot

March 2025

Radiopharmacy Unit, Department of Pharmacy, Groupement Hospitalier Sud - Hospices Civils de Lyon, 165 chemin du Grand Revoyet, 69495, Pierre-Bénite, France; Department of Pharmacy - Groupement Hospitalier Sud - Hospices Civils de Lyon, 165 chemin du Grand Revoyet, 69495, Pierre-Bénite, France.

For hepatobiliary scintigraphy, the radiopharmaceutical drug, ETIFENIN (TECHIDA®), labelled with technetium-99m, is used as a substitute for MEBROFENIN (CHOLEDIAM®). It is generally accepted that radiopharmaceuticals should be checked prior to injection, in particular by determining radiochemical purity, to ensure high-quality images. Radiochromatographic techniques or methods described in the Summary of Product Characteristics (SmPC) and the European Pharmacopeia (Ph.

View Article and Find Full Text PDF

Time-efficient HPLC Validation Methodology for the Qualitative Analysis of 68Ga PSMA-11 in Routine Clinical Usage under Isocratic Method.

Indian J Nucl Med

November 2024

Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute, Varanasi, Uttar Pradesh, India.

Background: Prostate-specific membrane antigen (PSMA) has shown to be a promising agent for prostate cancer imaging under PET-CT. With the automation in radiolabeling with 68Ga, using iTG 68Ge/68Ga generator, it has helped introduce various new diagnostic agents and achieve good manufacturing practices (GMP) simultaneously. However, before any radiopharmaceutical is put into clinical usage, it should always be checked for its radiochemical purity and other quality parameters before injecting in the patient.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!