Aortic valve leaflets undergo extraordinary flexion due to the complete reversal of their curvature during billions of cardiac cycles. The flexion stresses in the leaflet depend on its elastic modulus which we investigated in vivo and in vitro. In six dogs, we placed radiopaque markers on an aortic leaflet. Leaflet length was calculated from the marker positions recorded fluoroscopically. Aortic and ventricular pressures were recorded. Dogs were killed and leaflet stress-strain curves determined in vitro. Leaflet length in vivo decreased 10.4 +/- 4.7% from diastole to systole in each cardiac cycle. Using the law of LaPlace, pressure gradients across the leaflets were converted into the stresses in the leaflets. The leaflets had an initial "elastic phase" of low modulus in systole followed by an "inelastic phase" of high modulus in diastole. The elastic modulus was 2.4 +/- 0.7 x 10(6) dynes/cm2 in systole and 5.2 +/- 1.7 x 10(7) dynes/cm2 in diastole. These results were similar to those obtained in vitro. Since flexion rigidity is proportional to (elastic modulus) x (thickness)3, the lower modulus in systole greatly reduces flexion stresses in the leaflet and increases leaflet longevity. The higher elastic modulus in diastole prevents excessive bulging or prolapse of the leaflet while it is subjected to the diastolic pressure gradient. We conclude that a natural or prosthetic leaflet which is thickened or has a high elastic modulus throughout the cardiac cycle will have a greater flexion stress that could cause early failure.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.res.47.5.792DOI Listing

Publication Analysis

Top Keywords

elastic modulus
24
leaflet
9
aortic valve
8
valve leaflets
8
vivo vitro
8
flexion stresses
8
stresses leaflet
8
modulus
8
leaflet length
8
cardiac cycle
8

Similar Publications

Transrectal shear wave elastography (T-SWE) can be used non-invasively to diagnose prostate cancer (PCa) and benign prostatic hyperplasia (BPH). The prostate tissue can be viewed as an ellipsoidal sphere with viscoelastic characterization. Linear elastic model has been used to characterize soft tissues, and the simplification of partial characterization provides incomplete information.

View Article and Find Full Text PDF

Lung progenitor (LP) cells identified by the expression of transcription factor NK2 homeobox 1 (NKX2.1) are essential for development of all lung epithelial cell types and hold tremendous potential for pulmonary research and translational regenerative medicine applications. Here we present engineered hydrogels as a promising alternative to the naturally derived materials that are often used to differentiate human induced pluripotent stem cells (iPSCs) into LP cells.

View Article and Find Full Text PDF

Owing to the differences in sedimentary environments in the mining areas of western China, the mechanical properties of rocks in this region are significantly different from those in the central and eastern regions. Therefore, uniaxial cyclic loading-unloading tests were conducted on fine sandstone found in many roof rocks to study the evolution laws of mechanical properties, deformation characteristics, acoustic emission (AE) parameters, and energy under cyclic loading and unloading conditions. The accumulated residual strain, dissipative energy, acoustic emission cumulative ringing counts, and cumulative energy were introduced to characterize the degree of rock damage.

View Article and Find Full Text PDF

A stretchable, adhesive, and wearable hydrogel-based patches based on a bilayer PVA composite for online monitoring of sweat by artificial intelligence-assisted smartphones.

Talanta

January 2025

Department of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, Tehran, 14588-89694, Iran; Center for Bioscience and Technology, Institute for Convergence Science and Technology, Sharif University of Technology, Tehran, 14588-89694, Iran; Fraunhofer Institute for Manufacturing Technology and Advanced Materials, 28359, Bremen, Germany. Electronic address:

Real-time monitoring of sweat using wearable devices faces challenges such as limited adhesion, mechanical flexibility, and accurate detection. In this work, we present a stretchable, adhesive, bilayer hydrogel-based patch designed for continuous monitoring of sweat pH and glucose levels using AI-assisted smartphones. The patch is composed of a bottom PVA hydrogel layer functionalized with colorimetric reagents and glucose oxidase enzyme, while the top PVA-sucrose layer enhances skin adhesion and protects against air moisture.

View Article and Find Full Text PDF

Generic Elasticity of Thermal, Underconstrained Systems.

Phys Rev Lett

December 2024

CPT, CNRS, Aix Marseille Univ, Université de Toulon, (UMR 7332), Turing Center for Living Systems, Marseille, France.

Athermal (i.e., zero-temperature) underconstrained systems are typically floppy, but they can be rigidified by the application of external strain, which is theoretically well understood.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!